Siemens 3RV2011-0JA25 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0JA25 SIRIUS Motor Protection Circuit Breake

MPN3RV2011-0JA25
Active

Siemens SIRIUS 3RV2011-0JA25, motor protection circuit breaker, CLASS 10, 100 kA breaking capacity at 400 V, screw and snap-on mounting onto 35 mm DIN rail, spring-loaded terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0JA25 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0JA25 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-0JA25 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0JA25 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0JA25 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)

Mechanical

3RV2011-0JA25 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0JA25 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0JA25 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor Protection Circuit Breaker for 400 V Panels

The Siemens SIRIUS 3RV2011-0JA25 is a motor protection circuit breaker designed for the main current circuit, with spring-loaded terminals and a CLASS 10 trip characteristic. That CLASS 10 rating means it will trip within 10 seconds at 7.2× the thermal setting — fast enough to protect standard induction motors during a locked-rotor event without nuisance tripping on normal start-up. Mounting is via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, in any position. The 45 mm width (three module spaces) and 97 mm depth fit standard distribution boards and motor control center buckets.

Breaking Capacity and Fault Coordination

Rated breaking capacity is 100 kA at 400 V, 500 V, and 690 V. That SCCR rating means the breaker can safely interrupt a fault current up to 100 kA without welding contacts or cascading failure upstream — critical for panel selectivity studies where the available fault current exceeds 50 kA. Phase failure detection is built in. If one phase drops out on a three-phase motor, the breaker trips — preventing single-phasing damage. Ground fault detection is not included, so for ground-fault protection you'd add a separate GFCI module or residual current device downstream.

Frequently asked questions

What is the breaking capacity of 3RV2011-0JA25 at 400 V?

The rated breaking capacity is 100 kA at 400 V, and the same 100 kA rating applies at 500 V and 690 V.

Will 3RV2011-0JA25 drop into a panel specified around 3RV2011-0BA20 without rewiring?

Both are 45 mm wide SIRIUS motor protection breakers with the same DIN rail mounting and spring-loaded terminal format, so the mechanical fit and wiring footprint are identical. The key difference is the 3RV2011-0JA25 carries a 100 kA breaking capacity at 400 V versus the lower-rated sibling, so verify the available fault current at the panel before swapping.

Where can I buy 3RV2011-0JA25 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3RV2011-0JA25