Skip to main content
Siemens 3RV2011-0JA25-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0JA25-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2011-0JA25-ZW96
Active

Siemens SIRIUS 3RV2011 motor protection circuit breaker, 3RV2011-0JA25-ZW96, Trip Class 10, 100 kA breaking capacity at 400 V, spring-loaded terminals, snap-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-0JA25-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-0JA25-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-0JA25-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-0JA25-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-0JA25-ZW96 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)
3RV2011-0JA25-ZW96 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2011-0JA25-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-0JA25-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

It combines a circuit breaker and overload relay in one unit, with Trip Class 10 protection. It also includes phase failure detection, so if one leg drops out, the breaker opens before the motor single-phases and cooks the winding.

Mounting and terminals

Any mounting position is allowed, which gives flexibility in tight cabinets. The main circuit uses spring-loaded terminals — no screwdriver needed for the power wires, just strip and push. Accepts 2 x 0.5 to 2.5 mm² solid or stranded. That 45 mm width is a single module on the rail — leaves room for other breakers or contactors in the row.

Environmental and aux ratings

Storage and transport range extends from -50 to +80 °C. Auxiliary contact ratings: 1 A at 24 V, 0.5 A at 120/125/230 V, 0.15 A at 60 V. Rated operational voltage spans 20 to 690 V AC.

Frequently asked questions

What is the depth of 3RV2011-0JA25-ZW96?

The depth is 97 mm.

What is the width of 3RV2011-0JA25-ZW96?

The width is 45 mm.

Will 3RV2011-0JA25-ZW96 drop into a panel specified for 3RV2011-0BA20 without rewiring?

Both are SIRIUS 3RV2011 motor protection circuit breakers with the same 45 mm width and DIN rail mounting, so mechanical fit should be identical. However, terminal type and auxiliary contact ratings may differ — verify the wiring diagram against your existing panel before swapping.

MPN