Siemens 3RV2011-0KA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0KA15 SIRIUS Motor Protection Circuit Breake

MPN3RV2011-0KA15
Active

Siemens SIRIUS motor-protection circuit breaker, 3RV2011-0KA15, 0.2 kW at 230 V, Trip Class 10, 100 kA breaking capacity at 400 V, screw terminals, DIN rail mount.

$38.10Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2011-0KA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-0KA15 — Electrical
ParameterValue
Rated operational current (Ie)1.25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-0KA15 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Instantaneous short-circuit trip current16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-0KA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-0KA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2011-0KA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-0KA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-0KA15 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor-protection circuit breaker for DIN-rail panels

The Siemens 3RV2011-0KA15 is a SIRIUS motor-protection circuit breaker designed for motor loads up to 0.2 kW at 230 V, with a Trip Class 10 thermal overload curve that matches standard induction-motor starting profiles — it holds during a normal start and trips on a stalled rotor within 10 seconds at 7.2× Ie. Rated breaking capacity of 100 kA at 400 V, 480 V, 500 V, and 690 V means it can interrupt a bolted fault at the motor terminals without upstream fuses — useful for high-SCCR panel designs where the motor branch needs to coordinate with a 100 kA-rated feeder.

Screw-type terminals on the main circuit accept 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) solid or stranded — no ferrule needed for the smaller range, but a ferrule helps with the 2.5 mm² stranded pair.

Frequently asked questions

Will 3RV2011-0KA15 drop into a panel specified around 3RV2011-0AA10 without rewiring?

Both are 45 mm wide SIRIUS motor-protection breakers with screw terminals on the same DIN-rail footprint, so mechanical fit is identical. The 0KA15 carries a higher breaking capacity (100 kA vs the 0AA10's lower rating) and includes phase failure detection — check the overload setting range against your motor FLA before swapping.

MPN
3RV2011-0KA15