Siemens 3RV2011-0KA25 — Motor Protection Circuit Breakers (MPCB)

Siemens SIRIUS 3RV2011-0KA25 Motor Protection Circuit Breake

MPN3RV2011-0KA25
Active

Siemens SIRIUS 3RV2011-0KA25 motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V, phase failure detection, spring-loaded terminals, 45 x 97 x 106 mm.

$38.10Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2011-0KA25 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-0KA25 — Electrical
ParameterValue
Rated operational current (Ie)1.25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-0KA25 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Instantaneous short-circuit trip current16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-0KA25 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-0KA25 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)
3RV2011-0KA25 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-0KA25 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-0KA25 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The 100 kA breaking capacity at 400 V (also 100 kA at 240 V, 500 V, and 690 V) lets this breaker sit upstream of a motor starter without requiring a separate current-limiting fuse in most industrial distribution panels. The main circuit uses spring-loaded terminals — no screw tightening needed, which speeds panel wiring and eliminates the risk of loose connections on high-vibration motor circuits.

Clearance requirements: 50 mm upwards and downwards, 30 mm at the sides — zero clearance forwards and backwards. That means the breaker can sit flush against the back panel and the enclosure door, but needs breathing space above and below for arc quenching and thermal dissipation.

Switching capacity and coordination

At 230 V, the motor power rating is 0.2 kW. The auxiliary contact ratings cover a range of control voltages: 1 A at 24 V, 0.5 A at 120/125/230 V, and 0.15 A at 60 V. The maximum operating rate is 15 switching cycles per hour for AC-3 and AC-3e duty — adequate for motor start/stop applications but not for high-speed jogging or reversing.

Frequently asked questions

What is the breaking capacity of 3RV2011-0KA25 at 400 V?

The breaking capacity is 100 kA at 400 V, and the same 100 kA rating applies at 240 V, 500 V, and 690 V. This high interrupting rating allows the breaker to be used in high-fault-current industrial panels without additional current-limiting fuses.

Does 3RV2011-0KA25 detect phase failure?

Yes, phase failure detection is built in. The breaker will trip if one phase is lost, protecting the motor from single-phasing damage. Ground fault detection is not included.

What trip class is 3RV2011-0KA25?

It is Class 10, which means it trips within 10 seconds at 7.2× the thermal current setting. This is the standard trip class for general-purpose motor protection, suitable for most standard induction motors.

How do I get current pricing and availability for 3RV2011-0KA25?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3RV2011-0KA25