Siemens 3RV2011-0KA25-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0KA25-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-0KA25-ZX95
Active

Siemens SIRIUS 3RV2011-0KA25-ZX95, motor protection circuit breaker, size S00, CLASS 10, A-release 0.9...1.25 A, short-circuit release 16 A, spring-type terminal, 1 NO + 1 NC auxiliary switch.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0KA25-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker

Electrical

3RV2011-0KA25-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)1.25 A
Rated voltage20 ... 690 V

Protection & Tripping

3RV2011-0KA25-ZX95 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current16 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA

Specifications

3RV2011-0KA25-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Other specifications

3RV2011-0KA25-ZX95 — Other specifications
ParameterValue
At 400 V rated value100 kA
At 500 V rated value100 kA
Substance prohibitance10/01/2009

Product details

What this breaker is and what it does

The Siemens SIRIUS 3RV2011-0KA25-ZX95 is a motor protection circuit breaker in size S00, designed to protect three-phase induction motors up to 1.25 A operational current. It combines a thermal overload release (CLASS 10 trip class) with a magnetic short-circuit release set at 16 A. The spring-type terminals accept solid or stranded copper up to 4 mm² — no screw torque to verify, which saves time on a panel build. The integrated transverse auxiliary switch (1 NO + 1 NC) gives a status signal back to the PLC or safety relay without needing a separate contact block.

Breaking capacity — 100 kA across the board

Rated breaking capacity holds at 100 kA from 240 V all the way up to 690 V AC. That means this breaker can sit upstream of a motor starter without worrying about cascading failure under a bolted fault — the SCCR headroom covers most industrial supply transformers. The 20...690 V rated operating voltage range lets it run on 400 V or 480 V distribution without a different variant.

Panel integration and mounting

Size S00 snaps onto 35 mm DIN rail per EN 60715. The spring terminals on the main circuit accept 2x (0.5...4 mm²) solid or stranded, or 2x (0.5...2.5 mm²) finely stranded with ferrule. No screwdriver needed for the power connections — strip to 8 mm, push the spring, insert the wire. The auxiliary switch terminals are also spring-loaded, same strip length. Side-by-side mounting at 0 mm spacing is allowed; no derating required for the 100 kA rating when ganged.

Compliance and documentation

RoHS compliant per the substance prohibition date of 10/01/2009. The SIRIUS 3RV series carries UL/CSA/CE/IEC certifications standard for motor-protective circuit breakers. The manufacturer provides a declaration of conformity and a full datasheet with time-current curves for coordination studies.

Frequently asked questions

Where can I buy 3RV2011-0KA25-ZX95 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the trip class of 3RV2011-0KA25-ZX95?

CLASS 10, meaning the bimetal overload release trips within 10 seconds at 600% of the set current — standard for standard-duty motor starting (not for high-inertia loads that need CLASS 20 or 30).

Will 3RV2011-0KA25-ZX95 drop into a panel specified for 3RV2011-0BA20?

Yes — same S00 footprint, same 45 mm width, same DIN-rail snap-on mounting. The -ZX95 variant adds the factory-fitted transverse auxiliary switch (1 NO + 1 NC) and spring terminals instead of screw terminals. No rewiring needed if the panel was laid out for the S00 form factor, but the spring terminals may require a different strip length or ferrule compared to the screw-clamp version.

What is the rated voltage range of 3RV2011-0KA25-ZX95?

20 to 690 V AC, covering 240 V, 400 V, 480 V, and 690 V distribution systems without needing a different variant.

What compliance documentation does this part carry?

RoHS compliant (substance prohibition date 10/01/2009). The SIRIUS series standardly carries UL, CSA, CE, and IEC certifications. A declaration of conformity and time-current curves are available from the manufacturer.