Siemens 3RV2011-1BA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1BA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2011-1BA10
Active

Siemens SIRIUS, motor protection circuit breaker, 3RV2011-1BA10, Class 10 trip, 100 kA at 400 V, screw terminals, 45 mm wide.

$99.61 – $180.99Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2011-1BA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1BA10 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1BA10 — Protection & Tripping
ParameterValue
Overload release setting range1.4 ... 2 A
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1BA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1BA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2011-1BA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1BA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1BA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

At 690 V the breaking capacity drops to 10 kA — still enough for most 690 V motor circuits. No ground fault detection on this variant, so pair it with a separate ground-fault relay if needed.

The 45 mm width means it takes up two standard 22.5 mm module spaces — slim enough for a crowded panel. That's the space needed to keep heat from building up and to allow the bimetal strip to track ambient correctly. If you cram it tighter, you'll nuisance-trip on a warm day.

What the ratings mean in practice

That's typical for a motor branch circuit fed by a large transformer. At 240 V the same 100 kA holds; at 690 V it's 10 kA. No derating curve is given in the spec, but standard practice is to reduce the thermal setting by about 0.5% per °C above 40 °C ambient. Keep that in mind if your panel sits next to a furnace.

Frequently asked questions

What are the key dimensions for panel layout?

Width 45 mm, height 97 mm, depth 97 mm. Clearance: 50 mm above and below, 30 mm sides, zero front/back.

What breaking capacity does it have at 400 V?

100 kA at 400 V AC. At 690 V it's 10 kA.

MPN
3RV2011-1BA10