Siemens 3RV2011-1BA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1BA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV2011-1BA10-ZW97
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1BA10-ZW97, Class 10, 100 kA breaking capacity at 400 V, 97x45x97 mm, screw and snap-on mounting on 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1BA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1BA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-1BA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range1.4 ... 2 A
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1BA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1BA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-1BA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1BA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1BA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker for panel integration

The Siemens SIRIUS 3RV2011-1BA10-ZW97 is a motor protection circuit breaker designed for Class 10 trip response, meaning it will open within 10 seconds at 7.2× the thermal setting — fast enough to protect standard induction motors during a locked-rotor event without nuisance tripping on normal starts. Rated breaking capacity hits 100 kA at 400 V and 500 V AC, and 10 kA at 690 V, so it can interrupt high fault currents upstream of a motor starter without cascading damage to downstream contactors or overloads. Mounts via screw and snap-on onto standard 35 mm DIN rail per DIN EN 60715, with a 45 mm width that fits a single modular device slot — no extra panel space needed beyond the contactor it pairs with.

Frequently asked questions

Will 3RV2011-1BA10-ZW97 drop into a panel specified around 3RV2011-0AA10 without rewiring?

Both use the same 45 mm width and screw/snap-on DIN rail mounting, so the footprint is identical — no panel rework needed for the swap.

MPN
3RV2011-1BA10-ZW97