Siemens SIRIUS, motor protection circuit breaker, 3RV2011-1BA20-ZW96, CLASS 10, 100 kA at 400 V AC, spring-loaded terminals, 45 x 97 x 106 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1BA20-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1BA20-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1BA20-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range1.4 ... 2 A
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1BA20-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1BA20-ZW96 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)
3RV2011-1BA20-ZW96 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2011-1BA20-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1BA20-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

DIN-rail mounting and panel fit

The 45 mm width occupies a single 9 mm modular-width slot on the rail — standard for a motor-protection device in a motor control center (MCC) bucket. Depth of 97 mm and height of 106 mm leave clearance for wiring ducts and adjacent devices; minimum spacing of 50 mm upwards and downwards and 30 mm at the sides ensures adequate heat dissipation for the thermal-magnetic trip mechanism.

Breaking capacity and fuse coordination

The 3RV2011-1BA20-ZW96 carries a 100 kA breaking capacity at 400 V AC and 500 V AC, dropping to 10 kA at 690 V. For applications above 690 V or where the available fault current exceeds the breaker's rating, the spec table shows required upstream gL/gG fuse ratings: 25 A at 400 V and 500 V, 20 A at 690 V. This coordination data is essential for the panel builder's arc-flash study and selective coordination study.

Operating temperature range of -20 to +60 °C with temperature compensation active across the same span keeps the thermal trip curve stable despite ambient shifts in a non-conditioned enclosure. Storage and transport range of -50 to +80 °C covers cold-weather warehousing and container shipping. The current lifecycle stage means no end-of-life notice is in effect; the part is specified into new BOMs without requalification risk.

Frequently asked questions

What is the breaking capacity of 3RV2011-1BA20-ZW96 at 400 V?

The breaking capacity is 100 kA at 400 V AC, suitable for high-fault-current industrial distribution panels.

What is the closest functional second-source for 3RV2011-1BA20-ZW96?

The 3RV1011-0GA10 is a smaller-frame SIRIUS motor protection breaker, but it carries a lower interrupting rating. The 3RV2011-1BA20-ZW96 is the correct choice when the available fault current exceeds 65 kA, as it provides 100 kA at 400 V AC.

Will 3RV2011-1BA20-ZW96 drop into a panel specified around 3RV1011-0GA10?

Both are SIRIUS motor protection breakers on the same 35 mm DIN-rail footprint, so the physical swap is straightforward. However, verify that the available fault current at the panel does not exceed the 3RV1011-0GA10's lower interrupting rating; the 3RV2011-1BA20-ZW96 provides 100 kA at 400 V AC, which may be higher than the original breaker's rating.

Where can I buy 3RV2011-1BA20-ZW96 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time commitment.

MPN