Siemens 3RV2011-1BA20-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1BA20-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-1BA20-ZX95
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1BA20-ZX95, Class 10 trip, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, 45 mm width.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1BA20-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1BA20-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-1BA20-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range1.4 ... 2 A
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1BA20-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1BA20-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)

Mechanical

3RV2011-1BA20-ZX95 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1BA20-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1BA20-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What this SIRIUS motor protection circuit breaker carries

The Siemens 3RV2011-1BA20-ZX95 is a SIRIUS motor protection circuit breaker. Its breaking capacity is 100 kA at 400 V AC and 10 kA at 690 V AC. Trip Class 10 means the bimetal releases within 10 seconds at 7.2× the thermal setting — fast enough to protect standard IEC induction motors from stall or locked-rotor conditions. Phase failure detection is built in, so a lost phase on a three-phase motor trips the breaker instead of letting the motor single-phase and burn. The 45 mm wide housing clips onto 35 mm DIN rail per EN 60715, with a 97 mm depth that leaves room for wiring behind the panel door. Spring-loaded terminals accept 2× (0.5 to 4 mm²) solid or stranded — no screw torque to verify, just strip and push. Mounting position is any, so it fits tight enclosures where you'd rather lay the rail horizontally.

Integration — what fits alongside it

The 45 mm width matches the standard SIRIUS contactor footprint. Clearance requirements: 50 mm above and below, 30 mm to the side, zero forward or backward. Operating temperature range is -20 to +60 °C, storage -50 to +80 °C. Spring-loaded terminals on the main circuit reduce wiring time on a panel build. The auxiliary contact block (not included) clips onto the side without increasing width — order separately if remote status or PLC feedback is needed.

Frequently asked questions

Will 3RV2011-1BA20-ZX95 drop into a panel specified around 3RV2011-0BA20 without rewiring?

The 3RV2011-1BA20-ZX95 shares the same 45 mm width, DIN-rail mounting, and spring-loaded terminal layout as the 3RV2011-0BA20. Physical fit and wiring are identical — the difference is in the internal trip setting range and accessories. Confirm the overload setting matches your motor FLA before swapping.