Skip to main content
Siemens 3RV2011-1BA25-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1BA25-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2011-1BA25-ZW96
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1BA25-ZW96, CLASS 10, 2 A operational current, 26 A short-circuit release, spring-type terminal, size S00.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1BA25-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
3RV2011-1BA25-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage20 ... 690 V
3RV2011-1BA25-ZW96 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
3RV2011-1BA25-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection
3RV2011-1BA25-ZW96 — Other specifications
ParameterValue
At 400 V rated value100 kA
At 500 V rated value100 kA
Substance prohibitance10/01/2009

Product details

Motor protection circuit breaker, SIRIUS, 2 A, CLASS 10

Rated operational current is 2 A, with a magnetic short-circuit release set at 26 A. The breaker handles fault currents up to 100 kA at 240 V, 400 V, and 500 V AC, and 10 kA at 690 V AC — sufficient for most industrial panel SCCR requirements when coordinated with upstream fuses or a main breaker. Termination is via spring-type terminals, which accept solid or stranded copper up to 4 mm² per conductor. The breaker ships with factory-installed transverse auxiliary switches: 1 NO + 1 NC contact for remote status indication or interlocking.

Side-by-side mounting is permitted with zero clearance — no derating required for adjacent units at the rated current.

Frequently asked questions

What is the trip class of 3RV2011-1BA25-ZW96?

The trip class is CLASS 10, meaning it will trip within 10 seconds at 7.2x the thermal setting.

What is the rated voltage range for this breaker?

The rated voltage range is 20 to 690 V AC.

Where can I buy 3RV2011-1BA25-ZW96 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Siemens provide for this breaker?

The part carries RoHS compliance dated 10/01/2009. The SIRIUS series is designed to meet IEC 60947 and UL 508 standards for motor protection.

MPN
3RV2011-1BA25-ZW96