Siemens 3RV2011-1BA25-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1BA25-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-1BA25-ZX95
Active

Siemens SIRIUS 3RV2011-1BA25-ZX95 motor protection circuit breaker, size S00, CLASS 10, A-release 1.4...2 A, short-circuit release 26 A, spring-type terminal, 1 NO + 1 NC auxiliary contacts.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1BA25-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker

Electrical

3RV2011-1BA25-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage20 ... 690 V

Protection & Tripping

3RV2011-1BA25-ZX95 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA

Specifications

3RV2011-1BA25-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Other specifications

3RV2011-1BA25-ZX95 — Other specifications
ParameterValue
At 400 V rated value100 kA
At 500 V rated value100 kA
Substance prohibitance10/01/2009

Product details

Siemens SIRIUS 3RV2011-1BA25-ZX95 is a motor protection circuit breaker, size S00, CLASS 10 trip. It protects motors up to 2 A full-load current. Rated operational current is 2 A, adjustable thermal overload release covers 1.4 to 2 A. Instantaneous short-circuit release is fixed at 26 A. Breaking capacity is 100 kA at 240 V, 400 V, and 500 V AC, derating to 10 kA at 690 V AC. That 100 kA rating at common distribution voltages (240/400 V) means this breaker can be installed on high-fault-capacity panels without needing upstream current-limiting fuses — it handles the full prospective fault current itself.

Termination and Mounting

This variant uses spring-type terminals on the main circuit, accepting 2×(0.5 to 1.5 mm²) solid/stranded or 2×(0.75 to 2.5 mm²) with ferrule. The spring cage eliminates screw-torque verification during panel build — strip to 8 mm, push the conductor in, done. Mounts via snap-on to 35 mm DIN rail per EN 60715; side-by-side spacing is 0 mm, so breakers pack tightly without derating. The built-in transverse auxiliary switch block provides 1 NO + 1 NC contact, rated C300 / R300 per UL. This covers remote status feedback or interlocks without adding a separate auxiliary module.

Frequently asked questions

What is the rated voltage range for 3RV2011-1BA25-ZX95?

The rated operational voltage is 20 to 690 V AC, covering standard low-voltage motor circuits up to 690 V.

Does 3RV2011-1BA25-ZX95 drop into a panel specified for 3RV2021-1FA15?

No — the 3RV2021-1FA15 is a size S0 breaker (45×97 mm footprint) with a higher 5 A rating and screw terminals, while this is a size S00 with spring terminals. Footprint and terminal style differ; panel rework would be required.