Skip to main content
Siemens 3RV2011-1CA15-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1CA15-0BA0 SIRIUS Motor Protection CB, CLASS

MPN3RV2011-1CA15-0BA0
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1CA15-0BA0, CLASS 10 trip, 100 kA breaking capacity at 400 V, screw terminals, 45 mm wide, DIN rail snap-on.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1CA15-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1CA15-0BA0 — Electrical
ParameterValue
Rated operational current (Ie)2.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1CA15-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Instantaneous short-circuit trip current33 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1CA15-0BA0 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)500
Endurance, auxiliary contacts (typ.)500
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1CA15-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2011-1CA15-0BA0 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2011-1CA15-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1CA15-0BA0 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens SIRIUS 3RV2011-1CA15-0BA0 is a motor protection circuit breaker designed for CLASS 10 trip characteristics, meaning it disconnects within 10 seconds at 7.2× the thermal setting — standard for protecting standard induction motors during locked-rotor conditions without nuisance tripping on normal starts. Rated breaking capacity hits 100 kA at 400 V and 500 V, and 10 kA at 690 V, so it handles high-fault-current panels without requiring upstream fuses in most industrial distributions. Width is 45 mm, depth 97 mm, height 97 mm — fits standard panel grids.

Panel Integration & Wiring

Screw-type terminals for the main circuit accept 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) solid or stranded copper; M3 screws on main contacts. Clearance distances: 50 mm upwards and downwards, 30 mm at the side, 0 mm forwards and backwards — so it can be packed tight front-to-back but needs vertical breathing room for arc quenching. Operating temperature range -50 to +60 °C with temperature compensation active -20 to +60 °C; storage and transport -50 to +80 °C.

Frequently asked questions

What is the width of 3RV2011-1CA15-0BA0?

45 mm width, 97 mm depth, 97 mm height.

MPN
3RV2011-1CA15-0BA0