Siemens 3RV2011-1DA15-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1DA15-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV2011-1DA15-ZW97
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1DA15-ZW97, Trip Class 10, 45 mm wide, screw and snap-on mounting onto 35 mm DIN rail, 100 kA breaking capacity at 400 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1DA15-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1DA15-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)3.2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1DA15-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range2.2 ... 3.2 A
Instantaneous short-circuit trip current42 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1DA15-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1DA15-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2011-1DA15-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1DA15-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1DA15-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Rated voltage spans 20 to 690 V, with a breaking capacity of 100 kA at both 240 V and 400 V, and 10 kA at 690 V.

DIN rail fit and clearance

Trip Class 10 and switching duty

Maximum switching frequency is 15 operations per hour in AC-3 and AC-3e duty, which covers most pump, fan, and conveyor applications. Auxiliary contact ratings: 1 A at 24 V, 0.5 A at 120/125/230 V, and 0.15 A at 60 V.

Frequently asked questions

What are the key ratings for 3RV2011-1DA15-ZW97?

It is a Trip Class 10 motor protection circuit breaker rated 20–690 V, with 100 kA breaking capacity at 400 V, 45 mm wide, and mounts on 35 mm DIN rail.

Where can I buy 3RV2011-1DA15-ZW97?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What clearance is needed around 3RV2011-1DA15-ZW97 in a panel?

Allow 50 mm above and below, 30 mm to the side. Zero clearance needed forward or backward.

MPN
3RV2011-1DA15-ZW97