Siemens 3RV2011-1EA10-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1EA10-0BA0 SIRIUS Motor Protection Circuit B

MPN3RV2011-1EA10-0BA0
Active

Siemens SIRIUS, motor protection circuit breaker, Size S00, 3RV2011-1EA10-0BA0, Trip Class 10, 100 kA breaking capacity at 400 V AC, gG 32 A at 400 V, screw and snap-on mounting onto 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1EA10-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1EA10-0BA0 — Electrical
ParameterValue
Rated operational current (Ie)4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-1EA10-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range2.8 ... 4 A
Instantaneous short-circuit trip current52 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1EA10-0BA0 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)500
Endurance, auxiliary contacts (typ.)500
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1EA10-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-1EA10-0BA0 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1EA10-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1EA10-0BA0 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

SIRIUS 3RV2011-1EA10-0BA0 Motor Protection Circuit Breaker

The Siemens 3RV2011-1EA10-0BA0 is a SIRIUS motor protection circuit breaker in Size S00, designed to protect motors against overload and short-circuit in a single device. Its Trip Class 10 means it trips within 10 seconds at 7.2× the thermal setting — the standard for standard-duty motor starting, not for high-inertia loads that need Class 20. The breaker detects phase failure, so a lost phase on the line side will drop the motor offline before single-phasing damages the winding. Breaking capacity is 100 kA at both 240 V and 400 V AC, which covers most industrial service-entrance and distribution-panel fault levels. At 690 V it drops to 4 kA — still adequate for 690 V motor branch circuits in steel or cement plants, but verify the available fault current at that voltage. The backup fuse recommendation at 690 V is gG 25 A; at 400 V and below, gG 32 A. Mounts via screw and snap-on onto 35 mm standard mounting rail per DIN EN 60715. The 45 mm width is the standard S00 footprint — fits alongside contactors in a coordinated starter assembly without extra spacing. Any mounting position is allowed, so it can go sideways in a tight panel as long as the ambient stays within -50 to +60 °C during operation.

Panel Fit — Size S00 Footprint

The 3RV2011-1EA10-0BA0 occupies the S00 frame: 45 mm wide, 97 mm deep, 97 mm tall. Clearance requirements are 50 mm upward and downward, 30 mm to the side, and zero forward or backward. That means it can be stacked tight front-to-back in a multi-row enclosure, but needs breathing room above and below for arc-quenching and terminal access. Terminals are screw-type for the main current circuit, accepting 2×(0.75…2.5 mm²) solid or stranded, or 2×4 mm². Screwdriver shaft diameter 5 to 6 mm, Pozidriv size 2 tip. No ground-fault detection built in — if GF protection is needed, add an external module or use a different SIRIUS variant.

Frequently asked questions

Where can I buy the 3RV2011-1EA10-0BA0 and get a price?

Sourced to order against an RFQ through independent distribution. Submit a request with your quantity; availability and current pricing are confirmed at quote time.

What is the breaking capacity of the 3RV2011-1EA10-0BA0 at 400 V?

100 kA at 400 V AC. At 690 V AC it is 4 kA. The backup fuse recommendation is gG 32 A at 400 V and below, gG 25 A at 690 V.

Will the 3RV2011-1EA10-0BA0 drop into a panel specified for the 3RV2011-0AA10?

Both are Size S00 with the same 45 mm width and 97 mm depth, so the mechanical footprint and DIN-rail clip are identical. The difference is in the internal trip range and accessories — verify the overload setting range of the -0AA10 against the -1EA10 before swapping. The mounting holes and terminal layout match.

MPN
3RV2011-1EA10-0BA0