Siemens 3RV2011-1EA15-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1EA15-0BA0 SIRIUS Motor Protection CB, Class

MPN3RV2011-1EA15-0BA0
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1EA15-0BA0, Trip Class 10, 100 kA breaking capacity at 400 V AC, 45 mm width, screw and snap-on mounting on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1EA15-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1EA15-0BA0 — Electrical
ParameterValue
Rated operational current (Ie)4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1EA15-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range2.8 ... 4 A
Instantaneous short-circuit trip current52 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1EA15-0BA0 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)500
Endurance, auxiliary contacts (typ.)500
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1EA15-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2011-1EA15-0BA0 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1EA15-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1EA15-0BA0 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

At 690 V AC the breaking capacity drops to 4 kA, so verify your system voltage against the rating table. Rated motor power is 0.8 kW at 230 V. The auxiliary contacts handle 1 A at 24 V and 0.5 A at 230 V — enough to signal a PLC input or drop out a contactor coil.

Panel integration

At 45 mm wide and 97 mm deep, it takes one standard DIN module slot. The screw-type terminals on the main circuit accept 2×(0.5…1.5 mm²) solid or stranded.

Frequently asked questions

Where can I buy 3RV2011-1EA15-0BA0?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — stock levels and lead time are confirmed at quote time.

What is the closest functional alternative to 3RV2011-1EA15-0BA0?

The 3RV2021-1FA15 is a physically similar SIRIUS motor protection breaker but carries different thermal setting ranges and breaking capacities. Verify your motor full-load current and available fault current against the 3RV2021-1FA15 datasheet before substituting — the 3RV2011-1EA15-0BA0 remains the direct fit for the original BOM line.

Will 3RV2011-1EA15-0BA0 drop into a panel wired for 3RV2021-1FA15?

Both mount on 35 mm DIN rail and share the same 45 mm width footprint, so mechanical fit is identical. However, the terminal layout and auxiliary contact configuration may differ — confirm wiring before swapping without a panel recheck.

What are the key specs of 3RV2011-1EA15-0BA0?

Trip Class 10, 100 kA breaking capacity at 400 V AC, 0.8 kW motor rating at 230 V, phase failure detection, 45 mm wide, 97 mm deep, screw-type terminals, DIN rail mount.

MPN
3RV2011-1EA15-0BA0