Siemens 3RV2011-1EA15-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1EA15-0BA0 SIRIUS Motor Protection CB, Class

MPN3RV2011-1EA15-0BA0
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1EA15-0BA0, Trip Class 10, 100 kA breaking capacity at 400 V AC, 45 mm width, screw and snap-on mounting on 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1EA15-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1EA15-0BA0 — Electrical
ParameterValue
Rated operational current (Ie)4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-1EA15-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range2.8 ... 4 A
Instantaneous short-circuit trip current52 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1EA15-0BA0 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)500
Endurance, auxiliary contacts (typ.)500
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1EA15-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-1EA15-0BA0 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1EA15-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1EA15-0BA0 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens SIRIUS 3RV2011-1EA15-0BA0 is a motor protection circuit breaker designed to protect three-phase motors against overload, short-circuit, and phase failure. Its Trip Class 10 means it trips within 10 seconds at 7.2× the thermal setting current, matching the startup profile of standard induction motors on conveyors, pumps, and fans.

Key ratings and what they mean for fit

The 100 kA breaking capacity at 400 V AC means this breaker can safely interrupt a fault current up to 100,000 A without welding contacts or cascading failure upstream — critical for panels with high available fault current from large transformers. At 690 V AC the breaking capacity drops to 4 kA, so verify your system voltage against the rating table. Rated motor power is 0.8 kW at 230 V. The auxiliary contacts handle 1 A at 24 V and 0.5 A at 230 V — enough to signal a PLC input or drop out a contactor coil. Phase failure detection is built in; no ground fault detection, so add a separate ground-fault relay if required.

Panel integration

Snaps onto 35 mm DIN rail per DIN EN 60715 or screws directly to a backplate. At 45 mm wide and 97 mm deep, it takes one standard DIN module slot. Mounting position is any, so it fits tight enclosures. The screw-type terminals on the main circuit accept 2×(0.5…1.5 mm²) solid or stranded.

Frequently asked questions

Where can I buy 3RV2011-1EA15-0BA0?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — stock levels and lead time are confirmed at quote time.

What is the closest functional alternative to 3RV2011-1EA15-0BA0?

The 3RV2021-1FA15 is a physically similar SIRIUS motor protection breaker but carries different thermal setting ranges and breaking capacities. Verify your motor full-load current and available fault current against the 3RV2021-1FA15 datasheet before substituting — the 3RV2011-1EA15-0BA0 remains the direct fit for the original BOM line.

Will 3RV2011-1EA15-0BA0 drop into a panel wired for 3RV2021-1FA15?

Both mount on 35 mm DIN rail and share the same 45 mm width footprint, so mechanical fit is identical. However, the terminal layout and auxiliary contact configuration may differ — confirm wiring before swapping without a panel recheck.

What are the key specs of 3RV2011-1EA15-0BA0?

Trip Class 10, 100 kA breaking capacity at 400 V AC, 0.8 kW motor rating at 230 V, phase failure detection, 45 mm wide, 97 mm deep, screw-type terminals, DIN rail mount.