Siemens 3RV2011-1EA25-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1EA25-0BA0 SIRIUS Motor Protection Circuit B

MPN3RV2011-1EA25-0BA0
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1EA25-0BA0, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, screw and snap-on 35 mm DIN rail mount, spring-loaded terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1EA25-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1EA25-0BA0 — Electrical
ParameterValue
Rated operational current (Ie)4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1EA25-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range2.8 ... 4 A
Instantaneous short-circuit trip current52 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1EA25-0BA0 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)500
Endurance, auxiliary contacts (typ.)500
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1EA25-0BA0 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²)
3RV2011-1EA25-0BA0 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1EA25-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1EA25-0BA0 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

It is a current-production part, actively sourced through independent distribution channels.

Any mounting position is permitted, so vertical or horizontal rail orientation is fine. Clearance requirements: 50 mm upwards, 50 mm downwards, 30 mm at the side, and 0 mm forwards and backwards. The 0 mm forward clearance means the breaker can be mounted flush against a panel door or cover without additional air gap. Main circuit terminals are spring-loaded (cage-clamp) type, accepting 2 × (0.5 to 2.5 mm²) solid or stranded wire. No screw torque to verify — strip to 8 mm and push in.

Frequently asked questions

What is the breaking capacity of 3RV2011-1EA25-0BA0 at 400 V?

100 kA at 400 V AC. At 690 V AC it is 4 kA.

What trip class is 3RV2011-1EA25-0BA0?

CLASS 10, meaning it trips within 10 seconds at 7.2× the thermal setting — standard for protecting standard induction motors.

Where can I buy 3RV2011-1EA25-0BA0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV2011-1EA25-0BA0