Skip to main content
Siemens 3RV2011-1FA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1FA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2011-1FA10-ZW96
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1FA10-ZW96, CLASS 10, screw-type terminals, 100 kA at 400 V, 45 mm wide, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1FA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1FA10-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1FA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range3.5 ... 5 A
Instantaneous short-circuit trip current65 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1FA10-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1FA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2011-1FA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1FA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1FA10-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

It is part of the SIRIUS series, a modular family of industrial control gear. The breaker offers a breaking capacity of 100 kA at 400 V and 500 V, and 4 kA at 690 V. At 240 V it also holds 100 kA.

Width is 45 mm (one standard modular unit), depth 97 mm, height 97 mm. Required clearances: 50 mm above and below the device, 30 mm to the side, zero forward or backward. These are the minimums for arc flash containment and thermal dissipation — a panel builder should respect them, especially when ganging multiple breakers. Terminals are screw-type for the main current circuit, accepting 2×(0.75–2.5 mm²) solid or stranded, or 2×4 mm². The main contact screws are M3. This is standard for panel wiring up to the breaker's rated current.

Lifecycle stage is current; no end-of-life notice on record. The supply channel is standard for SIRIUS components: sourced on request, with pricing and lead time confirmed at quote time.

Frequently asked questions

Where can I buy the 3RV2011-1FA10-ZW96?

This part is sourced through independent industrial automation distribution. Submit an RFQ for current pricing and availability; the item is quoted to order.

MPN
3RV2011-1FA10-ZW96