Skip to main content
Siemens 3RV2011-1FA15-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1FA15-ZW96 SIRIUS Motor Circuit Breaker, Cla

MPN3RV2011-1FA15-ZW96
Active

Siemens SIRIUS 3RV2011-1FA15-ZW96 motor-protective circuit breaker, Class 10, 45 mm wide, 100 kA breaking capacity at 400 V, phase failure detection, screw terminals, snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1FA15-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1FA15-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1FA15-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range3.5 ... 5 A
Instantaneous short-circuit trip current65 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1FA15-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1FA15-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2011-1FA15-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1FA15-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1FA15-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens 3RV2011-1FA15-ZW96 is a SIRIUS motor-protective circuit breaker designed to protect motors against overload, short circuit, and phase failure.

Rated breaking capacity hits 100 kA at 240 V, 400 V, and 500 V, dropping to 4 kA at 690 V. That 100 kA figure at common industrial voltages (400 V three-phase) means this breaker can clear a bolted fault without upstream devices having to open — it's selective with most standard feeder breakers in the panel. No ground fault detection here, so if that's needed, you'll add a separate GF relay or specify a different variant.

At 45 mm wide, it occupies a single DIN-rail module space. The screw-type terminals accept 2x 0.5–1.5 mm² or 2x 0.75–2.5 mm² solid or stranded copper. Use M3 screws for the main contacts. Rated operational voltage spans 20 to 690 V AC, covering most low-voltage industrial systems. The auxiliary contact ratings vary by voltage: 1 A at 24 V, 0.5 A at 120/125/230 V, and 0.15 A at 60 V.

Frequently asked questions

How do I get pricing and availability for 3RV2011-1FA15-ZW96?

Pricing and availability are confirmed at quote time against an RFQ through independent distribution channels.

Will 3RV2011-1FA15-ZW96 drop into a panel specified around 3RV1011-1HA10?

No, the 3RV1011-1HA10 is a different frame size and footprint — it will not directly interchange without panel modifications. The 3RV2011-1FA15-ZW96 is 45 mm wide versus the 3RV1011's 55 mm width, and terminal arrangements differ.

What are the key ratings of 3RV2011-1FA15-ZW96?

Trip Class 10, 100 kA breaking capacity at 400 V, phase failure detection, voltage range 20–690 V, operating temperature -20 to +60 °C, and screw terminals accepting up to 2.5 mm² conductors.

MPN
3RV2011-1FA15-ZW96