Skip to main content
Siemens 3RV2011-1GA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1GA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2011-1GA10-ZW96
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1GA10-ZW96, Class 10 trip class, 100 kA breaking capacity at 400 V, screw-type terminals, for 35 mm DIN rail per EN 60715.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1GA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1GA10-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)6.3 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1GA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range4.5 ... 6.3 A
Instantaneous short-circuit trip current82 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1GA10-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1GA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2011-1GA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2011-1GA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1GA10-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The rated insulation voltage spans 20 to 690 V, so it's suitable for 400 V and 480 V panels as well as 690 V installations.

Clearance requirements: 50 mm upwards, 50 mm downwards, 30 mm at the side, zero forwards and backwards. That means it can sit tight against the back panel and the cabinet door, but needs headroom and footroom for wiring and arc deflection. Main contact terminals are M3 screws, accepting 2×(0.75 to 2.5 mm²) solid or stranded, or 2×4 mm².

The lifecycle stage is current — this is an active, in-production Siemens SIRIUS catalog item. No end-of-life notice or successor has been issued.

Frequently asked questions

What is the breaking capacity of 3RV2011-1GA10-ZW96 at 400 V?

100 kA at 400 V. Also 100 kA at 240 V, 100 kA at 500 V, and 4 kA at 690 V.

Where can I buy 3RV2011-1GA10-ZW96 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3RV2011-1GA10-ZW96