Skip to main content
Siemens 3RV2011-1GA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1GA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2011-1GA10-ZW96
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1GA10-ZW96, Class 10 trip class, 100 kA breaking capacity at 400 V, screw-type terminals, for 35 mm DIN rail per EN 60715.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1GA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1GA10-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)6.3 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-1GA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range4.5 ... 6.3 A
Instantaneous short-circuit trip current82 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1GA10-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1GA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12

Mechanical

3RV2011-1GA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1GA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1GA10-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What this breaker does and what the ratings mean

The Siemens SIRIUS 3RV2011-1GA10-ZW96 is a motor protection circuit breaker designed to protect induction motors against overload and short-circuit. The Class 10 trip class means it will trip within 10 seconds at 7.2× the thermal setting — that's fast enough to protect a standard motor during a stalled-rotor condition without nuisance tripping on a normal start. Phase failure detection is built in, so a lost phase on the line side will trip the breaker rather than letting the motor single-phase and burn. The breaking capacity is 100 kA at 400 V and also at 240 V. That's a very high figure for a motor-protective device — it means this breaker can safely interrupt a fault current up to 100,000 A at those voltages without welding contacts or rupturing the case. At 690 V the rating drops to 4 kA, which still covers most industrial motor branch circuits on a 690 V system. The rated insulation voltage spans 20 to 690 V, so it's suitable for 400 V and 480 V panels as well as 690 V installations.

Mounting and panel integration

Mounts via screw or snap-on onto a 35 mm standard mounting rail per DIN EN 60715. The mounting position is any — no derating for horizontal or inverted orientation. Dimensions: 45 mm wide, 97 mm deep, 97 mm high. Clearance requirements: 50 mm upwards, 50 mm downwards, 30 mm at the side, zero forwards and backwards. That means it can sit tight against the back panel and the cabinet door, but needs headroom and footroom for wiring and arc deflection. Main contact terminals are M3 screws, accepting 2×(0.75 to 2.5 mm²) solid or stranded, or 2×4 mm². Screw-type terminals for the main current circuit — standard for panel builders who prefer screw clamping over spring-cage for motor branch circuits.

Lifecycle and sourcing reality

The lifecycle stage is current — this is an active, in-production Siemens SIRIUS catalog item. No end-of-life notice or successor has been issued. For a BOM line that calls out 3RV2011-1GA10-ZW96, this is the direct fit: same dimensions, same trip curve, same breaking capacity. Sourced to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Frequently asked questions

What is the breaking capacity of 3RV2011-1GA10-ZW96 at 400 V?

100 kA at 400 V. Also 100 kA at 240 V, 100 kA at 500 V, and 4 kA at 690 V.

Where can I buy 3RV2011-1GA10-ZW96 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3RV2011-1GA10-ZW96