Siemens 3RV2011-1GA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1GA15 SIRIUS Motor Protection Circuit Breake

MPN3RV2011-1GA15
Active

Siemens SIRIUS 3RV2011-1GA15 motor protection circuit breaker, 6.3 A at 480 V, 100 kA breaking capacity at 400 V, Class 10 trip, phase failure detection, current production.

$137.73Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2011-1GA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1GA15 — Electrical
ParameterValue
Rated operational current (Ie)6.3 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1GA15 — Protection & Tripping
ParameterValue
Overload release setting range4.5 ... 6.3 A
Instantaneous short-circuit trip current82 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1GA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1GA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2011-1GA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1GA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1GA15 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens SIRIUS 3RV2011-1GA15 is a motor protection circuit breaker designed for Class 10 trip characteristics, rated 6.3 A at 480 V and delivering 100 kA breaking capacity at 400 V.

The 3RV2011-1GA15 is rated 6.3 A at both 480 V and 600 V, with a breaking capacity of 100 kA at 240 V, 400 V, and 500 V. The voltage range covers 20 to 690 V, and the operating temperature spans -20 to +60 °C. Trip Class 10 means the breaker will trip within 10 seconds at 7.2× the set current, matching standard motor starting curves for most induction motors up to 6.3 A FLA.

The main contact terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire. Required clearance: 50 mm upward, 50 mm downward, 30 mm at the side.

Frequently asked questions

What is the breaking capacity at 400 V?

100 kA at 400 V.

Does it include phase failure detection?

Yes, phase failure detection is included.

What are the mounting clearances?

50 mm upward, 50 mm downward, 30 mm at the side.

MPN
3RV2011-1GA15