Skip to main content
Siemens 3RV2011-1GA15-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1GA15-0BA0 SIRIUS Motor Protection Circuit B

MPN3RV2011-1GA15-0BA0
Active

Siemens SIRIUS 3RV2011-1GA15-0BA0, motor protection circuit breaker, Class 10, 100 kA breaking capacity at 400 V AC, screw-type terminals, snap-on mounting on 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1GA15-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1GA15-0BA0 — Electrical
ParameterValue
Rated operational current (Ie)6.3 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-1GA15-0BA0 — Protection & Tripping
ParameterValue
Overload release setting range4.5 ... 6.3 A
Instantaneous short-circuit trip current82 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1GA15-0BA0 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)500
Endurance, auxiliary contacts (typ.)500
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1GA15-0BA0 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-1GA15-0BA0 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1GA15-0BA0 — Environmental
ParameterValue
Operating temperature-50 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1GA15-0BA0 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What it is and what it does

The Siemens SIRIUS 3RV2011-1GA15-0BA0 is a motor protection circuit breaker designed to protect three-phase motors against overload and short-circuit. It is rated for motor protection (Class 10 trip curve) and includes phase failure detection, so it will trip if one phase drops out — a common failure mode that can single-phase a motor and burn it out. Breaking capacity is 100 kA at 400 V AC, which means it can safely interrupt a fault current up to that level without cascading upstream — typical for industrial panel feeders where available fault current is high. At 690 V AC the rating drops to 4 kA, so verify the available fault current at your supply voltage.

Mounting and integration

Fastens with screws or snaps onto a 35 mm standard mounting rail per DIN EN 60715. Dimensions are 97 mm deep, 45 mm wide, 97 mm high — a compact footprint that fits a standard 45 mm-wide DIN slot. Mounting position is any, so it works in horizontal or vertical panel layouts. Clearance: 50 mm upwards and downwards, 30 mm to the side — enough for wiring access and heat dissipation. Screw-type terminals on the main circuit accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire. The terminal screw size is M3.

Frequently asked questions

What is the closest functional second-source to 3RV2011-1GA15-0BA0?

The closest peer within the same SIRIUS family is 3RV2021-1GA15. Both are motor-protection breakers with Class 10 trip and screw terminals, but the 3RV2021 series uses a different frame size — verify panel cutout and mounting rail compatibility before substituting.

MPN
3RV2011-1GA15-0BA0