Skip to main content
Siemens 3RV2011-1HA15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1HA15-ZX95 Motor Protection Circuit Breaker,

MPN3RV2011-1HA15-ZX95
Active

Siemens SIRIUS 3RV2011-1HA15-ZX95 motor protection circuit breaker, CLASS 10 trip, 8 A at 480 V, 100 kA breaking at 400 V, screw and snap-on DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1HA15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1HA15-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV2011-1HA15-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range5.5 ... 8 A
Instantaneous short-circuit trip current104 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1HA15-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1HA15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-1HA15-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1HA15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1HA15-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What this part is and what it does

The Siemens 3RV2011-1HA15-ZX95 is a SIRIUS motor protection circuit breaker designed to protect three-phase motors against overload and short circuit. Its CLASS 10 trip characteristic means it disconnects within 10 seconds at 7.2× the thermal setting — fast enough to protect standard induction motors during a locked-rotor event without nuisance tripping on normal starting inrush. The breaker includes phase failure detection, so a lost phase on the line side will trip the load before single-phasing damages the winding. Rated operating voltage spans 20 to 690 V AC, with a short-circuit breaking capacity of 100 kA at both 240 V and 400 V. At 480 V the rated current is 8 A, and at 600 V it is also 8 A. The motor horsepower rating is 1 hp at 230 V. These ratings mean the breaker can be used on a 480 V line feeding a small motor — say a 1 hp pump or conveyor — and still clear a bolted fault upstream without the main fuse needing to open.

Mounting and integration

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. The 45 mm width (three 17.5 mm modules) fits standard DIN-rail enclosures. Mounting position is any — vertical, horizontal, or flat — so panel layout is flexible. Clearance requirements: 50 mm upward and downward, 30 mm at the side. Main contact terminals accept M3 screws and 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded wire. Auxiliary contact ratings: 1 A at 24 V, 0.5 A at 120/125/230 V, 0.15 A at 60 V.

Frequently asked questions

What are the key ratings for 3RV2011-1HA15-ZX95?

CLASS 10 trip, rated voltage 20–690 V AC, short-circuit breaking 100 kA at 400 V, rated current 8 A at 480 V, phase failure detection included.

Where can I buy 3RV2011-1HA15-ZX95?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

What is the depth of 3RV2011-1HA15-ZX95?

97 mm.

What is the width of 3RV2011-1HA15-ZX95?

45 mm.

MPN
3RV2011-1HA15-ZX95