Siemens 3RV2011-1HA20 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1HA20 SIRIUS Motor Protection Circuit Breake

MPN3RV2011-1HA20
Active

Siemens SIRIUS 3RV2011-1HA20 motor protection circuit breaker, Trip Class 10, 100 kA SCCR at 400 V, phase failure detection, spring-loaded terminals, 45 mm wide.

$98.20Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2011-1HA20 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1HA20 — Electrical
ParameterValue
Rated operational current (Ie)8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2011-1HA20 — Protection & Tripping
ParameterValue
Overload release setting range5.5 ... 8 A
Instantaneous short-circuit trip current104 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1HA20 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1HA20 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)
3RV2011-1HA20 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1HA20 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1HA20 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Rated SCCR of 100 kA at 400 V and 240 V — that's the fault current it can interrupt without welding its own contacts shut. At 500 V it's 42 kA, at 690 V it's 4 kA. Those numbers govern whether this breaker coordinates with the upstream fuse or main, so if you're building a panel for a 400 V line, you've got headroom to the bus. No ground-fault detection on this variant, so keep that in mind if the application needs it separately.

Mounting position any, so you can lay it sideways in a tight gland plate if needed. No screw torque to check, just strip and push. Keep the strip length right and you won't chase a loose connection later. That's the ventilation and arc-chamber space; pack it tighter and the thermal trip shifts.

Current production — not a last-time-buy or NRND. If it's riding in a truck across a desert or sitting in a hot warehouse, that storage range covers it. The fuse backup ratings are given: at 400 V use gL/gG 50 A, at 500 V 40 A, at 690 V 35 A. Those are the max upstream fuse sizes to maintain the SCCR — don't oversize them or you lose the coordination.

Frequently asked questions

Does the 3RV2011-1HA20 include ground fault detection?

No, ground fault detection is not included on this variant.

What clearance is needed around this breaker?

50 mm above and below, 30 mm to the sides, zero forward or backward.