Siemens SIRIUS 3RV2011-1HA20-ZW97 motor protection circuit breaker, Trip Class 10, 50 A gL/gG at 400 V, 100 kA breaking capacity, screw and snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1HA20-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1HA20-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2011-1HA20-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range5.5 ... 8 A
Instantaneous short-circuit trip current104 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1HA20-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1HA20-ZW97 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)
3RV2011-1HA20-ZW97 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2011-1HA20-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1HA20-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The breaker is rated for 50 A gL/gG at 400 V, with a short-circuit breaking capacity of 100 kA at 400 V, so it can safely interrupt high-fault currents on a 400 V distribution system without needing an upstream current-limiting device.

The 45 mm width and 97 mm depth fit a standard 45 mm-wide DIN slot — no extra side clearance needed beyond 30 mm at the side and 50 mm above/below for ventilation and wiring access.

Frequently asked questions

What is the breaking capacity of this circuit breaker at 400 V?

100 kA at 400 V rated value, which means it can safely interrupt fault currents up to 100,000 amps on a 400 V system.

Where can I buy 3RV2011-1HA20-ZW97 and how is it quoted?

Sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is listed here.

Will 3RV2011-1HA20-ZW97 drop into a panel specified for 3RV2011-0BA20?

Both share the same 45 mm width and DIN rail mounting, but the 3RV2011-1HA20-ZW97 carries a higher 50 A gL/gG rating at 400 V versus the 0BA20's lower rating — verify the thermal setting range and load current before swapping without rewiring.

MPN