Siemens 3RV2011-1KA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1KA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2011-1KA10-ZW96
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1KA10-ZW96, Trip Class 10, 100 kA breaking capacity at 400 V, screw-type terminals, 45 mm width, for 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1KA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1KA10-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)12.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV2011-1KA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range9 ... 12.5 A
Instantaneous short-circuit trip current163 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1KA10-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1KA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-1KA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1KA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1KA10-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor Protection Circuit Breaker, Trip Class 10 — SIRIUS 3RV2011-1KA10-ZW96

The Siemens 3RV2011-1KA10-ZW96 is a SIRIUS-brand motor protection circuit breaker with Trip Class 10. Rated operating voltage spans 20... 690 V, with a breaking capacity of 100 kA at 400 V and 42 kA at 500 V. At 690 V the interrupting rating drops to 4 kA, so verify the available fault current at the installation point when applying this breaker on a 690 V line. Back-up fuse coordination is specified: gL/gG 63 A at 400 V, 50 A at 500 V, and 40 A at 690 V. These are the maximum upstream fuse ratings that preserve the breaker's interrupting capacity under short-circuit conditions. Phase failure detection is built in — the breaker will trip on loss of one phase, preventing single-phasing damage to the motor. Ground fault detection is not included, so a separate ground-fault relay or RCD is needed if that function is required.

Mounting and Integration

Fastens via screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. The 45 mm width fits standard panel layout grids. Mounting position is any orientation. Clearance distances: 50 mm upwards and downwards, 30 mm at the sides, 0 mm forwards and backwards. These are the minimum air gaps to adjacent metalwork or other devices for proper arc quenching and heat dissipation. Main circuit terminals accept 2×(0.75... 2.5 mm²) solid or stranded, or 2×4 mm². Screw size is M3 for the main contacts. Dimensions: 97 mm depth, 45 mm width, 97 mm height. The compact footprint leaves room for additional devices in the same row.

Operating Conditions and Switching Duty

Ambient operating temperature range is -20... +60 °C; storage and transport range is -50... +80 °C. The wider storage limit governs handling and warehousing, not running conditions. Maximum switching frequency is 15 operations per hour under AC-3 (motor starting) duty, and the same under AC-3e (enhanced motor protection) duty. This limits the breaker to applications with infrequent starts — not suitable for high-cycle jogging or reversing service. Motor horsepower ratings: 2 hp at 230 V, 3 hp at 200/208 V and 220/230 V, 8 hp at 460/480 V, and 0.5 hp at 110/120 V. These are the maximum motor sizes the breaker can protect at those voltages.

Frequently asked questions

What is 3RV2011-1KA10-ZW96's listed depth?

The depth is 97 mm.