Siemens 3RV2021-0JA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2021-0JA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2021-0JA10-ZW96
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2021-0JA10-ZW96, Class 10 trip, 100 kA breaking capacity at 400 V AC, size S0, screw and snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2021-0JA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV2021-0JA10-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2021-0JA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2021-0JA10-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2021-0JA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
Conductor range, AWG (main contacts)2x (16 ... 12), 2x (14 ... 8)
3RV2021-0JA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2021-0JA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2021-0JA10-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Rated breaking capacity hits 100 kA at 400 V AC and holds that 100 kA across the 240 V, 500 V, and 690 V AC ratings too — so it handles high-fault utility feeds without needing an upstream current-limiting fuse in most panels.

That keeps the arc-chamber vents unobstructed and meets the manufacturer's spacing for full breaking capacity. Main-circuit terminals accept 2x 1–2.5 mm² or 2x 2.5–10 mm² solid/stranded; screwdriver shaft 5–6 mm. M4 terminal screws on the main contacts.

Frequently asked questions

Will 3RV2021-0JA10-ZW96 drop into a panel designed for 3RV2011-0AA10?

Both are S0-frame breakers with the same 45 mm width and 97 mm depth, so the footprint and DIN-rail clip pattern are identical — no rewiring or backplate modification needed for the mechanical fit. Verify the trip current setting and terminal lug size against your existing wiring; the 3RV2021 variant carries a higher 100 kA breaking capacity across the voltage range.

MPN
3RV2021-0JA10-ZW96