Skip to main content
Siemens 3RV2021-0JA25 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2021-0JA25 SIRIUS Motor Circuit Breaker, 100 kA

MPN3RV2021-0JA25
Active

Siemens SIRIUS, motor-protective circuit breaker, 3RV2021-0JA25, CLASS 10 trip, 100 kA breaking capacity at 400 V AC, 45 mm wide, screw and snap-on DIN-rail mount.

$38.10Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2021-0JA25 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV2021-0JA25 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2021-0JA25 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2021-0JA25 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2021-0JA25 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 8)
3RV2021-0JA25 — Mechanical
ParameterValue
Height119 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2021-0JA25 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2021-0JA25 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens 3RV2021-0JA25 is a SIRIUS motor-protective circuit breaker designed for motor protection with CLASS 10 trip characteristics, meaning it will trip within 10 seconds at 7.2× the thermal setting — fast enough to protect a standard induction motor during a locked-rotor start but slow enough to ride through normal acceleration. Rated breaking capacity hits 100 kA at 400 V AC (and at 240 V, 500 V, and 690 V), so this breaker can safely interrupt fault currents up to that level without upstream fusing in most industrial panels — a key spec for high-fault-capacity installations. At 45 mm wide, it occupies a single 45 mm slot on the rail — standard for this class of motor-protective device.

The depth is the critical fit dimension for enclosure depth — 97 mm clears most standard shallow enclosures (100 mm minimum internal depth), but verify your gland plate and busbar clearance. Terminals are spring-loaded for the main current circuit, accepting 2× (0.5 to 2.5 mm²) solid or stranded. No screw torque to verify on the spring-cage side; strip length and ferrule size are the only variables. Auxiliary contact space is available on the side. Clearance distances: 50 mm upwards and downwards, 30 mm at the side, 0 mm forwards and backwards. The zero forward/backward clearance means it can be mounted flush against a backplate or panel door — no extra breathing space needed in those axes.

Storage and transport range: -50 to +80 °C.

Ratings and selection notes

Ground fault detection is not included; if that's required, add an external ground-fault module or specify a different variant. Rated operational voltage range: 20 to 690 V AC. Power ratings: 0.2 kW at 230 V, 0.5 hp at 575/600 V. Auxiliary contact ratings: 1 A at 24 V, 0.5 A at 120/125/230 V, 0.15 A at 60 V — these are the dry-contact switching limits for the integrated auxiliary contacts. Maximum switching frequency at AC-3 duty: 15 operations per hour. That's the thermal limit for motor starting — fine for pump or fan cycling, but not for high-repetition applications like stamping presses or rapid indexing.

Frequently asked questions

What is the breaking capacity of the 3RV2021-0JA25?

100 kA at 240 V, 400 V, 500 V, and 690 V AC — this covers most industrial fault-current scenarios without upstream fusing.

What are the mounting dimensions for the 3RV2021-0JA25?

45 mm wide, 97 mm deep, 119 mm tall. It snaps onto a 35 mm DIN rail per DIN EN 60715, with zero forward/backward clearance required.

Where can I buy the 3RV2021-0JA25 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a binding commercial offer.

Will the 3RV2021-0JA25 drop into a panel designed for the 3RV1011-0GA10?

Both are 45 mm wide SIRIUS motor-protective breakers on the same DIN-rail footprint, so mechanical fit is identical. Verify the trip class and setting range match your motor protection curve — the 3RV2021-0JA25 is CLASS 10, while the 3RV1011-0GA10 may differ.

MPN
3RV2021-0JA25