3RV2021-1AA20-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV2021-1AA20-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)1.6 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2021-1AA20-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Instantaneous short-circuit trip current21 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2021-1AA20-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2021-1AA20-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 6 mm²)
Conductor range, AWG (main contacts)2x (18 ... 8)
3RV2021-1AA20-ZX95 — Mechanical
ParameterValue
Height119 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2021-1AA20-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2021-1AA20-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

It trips on overload within Class 10 time limits — that means it clears a stalled-rotor condition fast enough to keep the motor winding insulation intact on most standard induction motors up to about 1 hp at 460/480 V.

The S0 frame footprint is 45 mm wide, 119 mm tall, 97 mm deep — that 97 mm depth is the dimension you need to clear the gland plate or backpanel. The screwdriver shaft spec is 3 mm diameter, which matches most standard terminal screwdrivers on a panel bench.

Frequently asked questions

How do I get current pricing and availability for 3RV2021-1AA20-ZX95?

Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time; no stock count or price is displayed on this page.

What is 3RV2021-1AA20-ZX95's listed depth?

The depth is 97 mm, measured from the mounting rail face to the furthest projecting point of the breaker body.

What is 3RV2021-1AA20-ZX95's listed width?

The width is 45 mm, which is the S0 frame standard — it occupies one 45 mm slot on a DIN rail.

Will 3RV2021-1AA20-ZX95 drop into a panel specified around 3RV2011-0BA20 without rewiring?

Both are S0 frame breakers with the same 45 mm width and 35 mm DIN rail mount, so the mechanical fit is identical. Terminal type and ratings differ — verify the main circuit connections and the trip curve match your load before swapping.

MPN