Siemens 3RV2021-1FA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2021-1FA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV2021-1FA10-ZW97
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2021-1FA10-ZW97, Trip Class 10, 100 kA breaking capacity at 400 V AC, 45 x 97 x 97 mm, screw and snap-on DIN rail mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2021-1FA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0

Electrical

3RV2021-1FA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2021-1FA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range3.5 ... 5 A
Instantaneous short-circuit trip current65 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2021-1FA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2021-1FA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²

Mechanical

3RV2021-1FA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2021-1FA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2021-1FA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker for panel integration

The Siemens 3RV2021-1FA10-ZW97 is a SIRIUS motor protection circuit breaker with Trip Class 10 thermal release and phase failure detection. Breaking capacity is 100 kA at both 240 V and 400 V AC, which covers most industrial distribution panels up to that fault level without needing an upstream current-limiting fuse. The 45 mm wide housing snaps onto 35 mm DIN rail per DIN EN 60715, and the screw terminals accept conductors up to 10 mm² stranded.

Lifecycle and sourcing posture

The 3RV2021-1FA10-ZW97 has a current lifecycle stage, meaning it remains in active Siemens production and distribution. The part is sourced to order through independent distribution; availability and pricing are confirmed at quote time.

Mounting and wiring constraints

Mounting position is any, so the breaker can be oriented vertically or horizontally inside the panel. Minimum clearance around the device: 50 mm upward, 50 mm downward, and 30 mm to the side — no clearance needed forward or backward. The main circuit terminals are M4 screws, and the terminal capacity is 2 × (1 to 2.5 mm²) or 2 × (2.5 to 10 mm²) solid or stranded. Ambient operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C.

Duty cycle and switching capacity

Maximum switching frequency in AC-3 duty (motor starting) is 15 operations per hour. At 690 V, the breaking capacity drops to 4 kA, so verify the available fault current at that voltage level. The rated operational voltage range is 20 to 690 V, covering most low-voltage motor circuits.

Frequently asked questions

What compliance documentation is available for this part?

The product is a Siemens SIRIUS device carrying CE marking for the European market. Specific declarations for RoHS, REACH, UL, and IEC compliance are available from Siemens upon request or through the product documentation portal.