Skip to main content
Siemens 3RV2021-1GA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2021-1GA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV2021-1GA10-ZW97
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2021-1GA10-ZW97, Trip Class 10, 100 kA breaking capacity at 400 V AC, phase failure detection, screw and snap-on mounting on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2021-1GA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV2021-1GA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)6.3 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2021-1GA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range4.5 ... 6.3 A
Instantaneous short-circuit trip current82 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2021-1GA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2021-1GA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
3RV2021-1GA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2021-1GA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2021-1GA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Its Trip Class 10 rating means it will trip within 10 seconds at 7.2× the thermal setting — a standard match for most general-purpose motor starts, including pumps, fans, and compressors. The 100 kA breaking capacity at 400 V AC gives it enough interrupting capability to sit on a high-fault panel without needing upstream fuses; the same rating holds at 240 V and 500 V. Any mounting position is allowed, so vertical or horizontal rail orientation works in tight enclosures.

The lifecycle stage for this order code is current production. That means it is still an active catalog item from Siemens, not a phase-out or NRND part. For a BOM line that calls out 3RV2021-1GA10-ZW97, the fit is confirmed by the Trip Class 10 and the 100 kA SCCR at 400 V — the two ratings that govern motor protection coordination.

Deployment context

The 45 mm width and 97 mm depth fit the standard 60 mm deep enclosure profile — no need for a deep gland plate. The screw-type terminals on the main current circuit accept solid or stranded conductors up to 2×10 mm², which covers the wire range for most motor circuits up to the 5 hp rating at 575/600 V.

Frequently asked questions

Where can I buy 3RV2021-1GA10-ZW97?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3RV2021-1GA10-ZW97 at 400 V?

100 kA at 400 V AC. The same 100 kA rating holds at 240 V and 500 V.

Does 3RV2021-1GA10-ZW97 include phase failure detection?

Yes, phase failure detection is built in.

What is the Trip Class of 3RV2021-1GA10-ZW97?

Trip Class 10, meaning it trips within 10 seconds at 7.2× the thermal setting — suited for standard motor starting.

MPN
3RV2021-1GA10-ZW97