Skip to main content
Siemens 3RV2021-1JA20 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2021-1JA20 SIRIUS Motor Protection Circuit Breake

MPN3RV2021-1JA20
Active

Siemens SIRIUS 3RV2021-1JA20 motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 400 V AC, spring-loaded terminals, 45 mm width.

StockContact for availability
Lead timeCall for availability wk
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2021-1JA20 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0

Electrical

3RV2021-1JA20 — Electrical
ParameterValue
Rated operational current (Ie)10 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W

Protection & Tripping

3RV2021-1JA20 — Protection & Tripping
ParameterValue
Overload release setting range7 ... 10 A
Instantaneous short-circuit trip current130 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2021-1JA20 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2021-1JA20 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 6 mm²)
Conductor range, AWG (main contacts)2x (18 ... 8)

Mechanical

3RV2021-1JA20 — Mechanical
ParameterValue
Height119 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2021-1JA20 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2021-1JA20 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens 3RV2021-1JA20 is a SIRIUS motor protection circuit breaker designed for motor protection. It carries a Class 10 trip characteristic, meaning it will trip within 10 seconds at 7.2× the thermal setting — the standard for protecting standard induction motors during start-up without nuisance tripping on normal acceleration. Rated breaking capacity hits 100 kA at 400 V AC, so it can safely interrupt high fault currents on industrial distribution without cascading upstream. Phase failure detection is built in — a critical feature for three-phase motor protection that prevents single-phasing damage. Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. The 45 mm width fits standard panel layout grids; depth is 97 mm. Spring-loaded terminals on the main circuit accept 2× (1–10 mm²) solid or stranded, speeding panel wiring.

Integration Notes

Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. Mounting position is any. Clearance requirements: 50 mm upwards, 50 mm downwards, 30 mm at the side, zero forwards or backwards. These spacings matter for heat dissipation and arc flash containment in a panel. Rated operational voltage spans 20 to 690 V. Maximum switching frequency under AC-3 duty is 15 operations per hour — sufficient for motor starting cycles on pumps, fans, and conveyors, but not for high-cycling applications like rapid reversing.

Frequently asked questions

What is the breaking capacity of the 3RV2021-1JA20?

100 kA at 400 V AC. At 500 V AC it is 42 kA; at 690 V AC it is 4 kA. These ratings cover most industrial motor branch circuits.

Where can I buy the 3RV2021-1JA20?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will the 3RV2021-1JA20 drop into a panel specified around the 3RV2021-1FA15?

Both are SIRIUS motor protection breakers with the same 45 mm width and DIN rail mounting, so the physical footprint is identical. The key difference is the 3RV2021-1JA20 carries a higher 100 kA breaking capacity at 400 V versus the 1FA15's lower rating — verify the SCCR requirement of your panel before swapping.

MPN
3RV2021-1JA20