Siemens 3RV2021-4BA25-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens SIRIUS 3RV2021-4BA25-ZX95 Motor Protection Circuit B

MPN3RV2021-4BA25-ZX95
Active

Siemens SIRIUS 3RV2021-4BA25-ZX95, motor protection circuit breaker, Class 10, 25 kA at 400 V, phase failure detection, spring-loaded terminals, 45 x 97 x 119 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2021-4BA25-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV2021-4BA25-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)20 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W
3RV2021-4BA25-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range13 ... 20 A
Instantaneous short-circuit trip current260 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)55 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2021-4BA25-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2021-4BA25-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²)
3RV2021-4BA25-ZX95 — Mechanical
ParameterValue
Height119 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2021-4BA25-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2021-4BA25-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection breaker for the SIRIUS line

The Siemens SIRIUS 3RV2021-4BA25-ZX95 is a motor protection circuit breaker designed to clear overloads and short circuits in motor branch circuits. It carries a 25 kA SCCR at 400 V AC, which means it can safely interrupt a fault current up to that level without upstream fuses or breakers needing to clear first — that is the rating that decides coordination in a panel. Trip Class 10 means it trips within 10 seconds at 7.2x rated current, fast enough to protect standard induction motors during a locked-rotor event. Phase failure detection is built in, so a dropped phase on the line side will trip the breaker rather than letting the motor single-phase and overheat.

DIN-rail fit and terminal style

Mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715 — the standard rail in any IEC panel. Mounting position is any orientation, which helps when fitting into tight gland-plate areas or vertical bus drops. The main circuit uses spring-loaded terminals accepting 2x 0.5 to 2.5 mm² solid or stranded; no screw torque to verify, no loosening under vibration. Dimensions are 45 mm wide, 97 mm deep, 119 mm high — this is a standard-width SIRIUS breaker that occupies one 45 mm slot on the rail, leaving the adjacent slots for contactors or overload relays.

Frequently asked questions

Where can I buy 3RV2021-4BA25-ZX95 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current pricing and availability at the time of order — no stock count or price figure is published here.

What is 3RV2021-4BA25-ZX95's SCCR at 400 V?

The short-circuit current rating at 400 V is 25 kA. This is the interrupting rating that governs coordination in a motor branch circuit — the breaker can clear a fault up to that level without upstream protection needing to intervene.

Does 3RV2021-4BA25-ZX95 detect phase failure?

Yes, phase failure detection is built in. If one line phase drops, the breaker will trip rather than allowing the motor to run single-phase, which prevents overheating and winding damage.

What terminal type does 3RV2021-4BA25-ZX95 use?

Spring-loaded terminals on the main current circuit, accepting 2x 0.5 to 2.5 mm² solid or stranded wire. No screw clamping — the spring cage holds the conductor, which speeds panel wiring and resists loosening under vibration.

Will 3RV2021-4BA25-ZX95 drop into a panel specified around 3RV1011-1HA10?

Not without rewiring. The 3RV1011-1HA10 is an S00 frame breaker with different dimensions, terminal style, and SCCR. The 3RV2021-4BA25-ZX95 is a physically larger S0/S2 frame unit (45 mm wide vs the S00's 45 mm but deeper and with different rail cutouts), and its spring-loaded terminals are not a direct match for the screw terminals on the 3RV1011. A panel designed for the S00 frame would need re-termination and possibly a new DIN-rail layout.

MPN