Siemens 3RV2021-4DA20-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2021-4DA20-ZX95 SIRIUS Motor Protection CB, 25 kA

MPN3RV2021-4DA20-ZX95
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2021-4DA20-ZX95, Trip Class 10, 100 kA at 240 V, 25 kA at 400 V, spring-loaded terminals, 45 mm wide.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2021-4DA20-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0

Electrical

3RV2021-4DA20-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)10.5 W
Power loss, per pole (AC, hot)3.5 W

Protection & Tripping

3RV2021-4DA20-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range18 ... 25 A
Instantaneous short-circuit trip current325 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)55 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2021-4DA20-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2021-4DA20-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 6 mm²)

Mechanical

3RV2021-4DA20-ZX95 — Mechanical
ParameterValue
Height119 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2021-4DA20-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2021-4DA20-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What it is and where it fits

The Siemens 3RV2021-4DA20-ZX95 is a SIRIUS motor protection circuit breaker — the device that sits between your contactor and the motor, combining overload protection and short-circuit interruption in one 45 mm-wide package. It snaps onto 35 mm DIN rail per DIN EN 60715 and terminates with spring-loaded terminals, so no screwdriver torque check after installation. The 97 mm depth means it clears standard 120 mm-deep enclosures with room for wiring behind the rail.

The ratings that matter for motor duty

Trip Class 10 means it will trip within 10 seconds at 7.2× rated current — fast enough to protect standard induction motors from locked-rotor heating, but not so fast it nuisance-trips on normal starting inrush. Phase failure detection is built in: if one phase drops, the breaker opens before single-phasing cooks the winding. At 240 V it interrupts 100 kA; at 400 V that drops to 25 kA — still enough for most industrial panel SCCR requirements. The gL/gG fuse coordination at 400 V is 63 A, meaning upstream fuse sizing is straightforward for selectivity.

Frequently asked questions

Where can I buy 3RV2021-4DA20-ZX95?

It is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

Will 3RV2021-4DA20-ZX95 drop into a panel specified around 3RV2021-4CA25 without rewiring?

Both are 45 mm wide SIRIUS motor protection breakers with the same DIN rail footprint and spring-loaded terminals, so the mechanical fit and wiring interface are identical. The difference is in the trip curve and interrupting ratings — verify the 4CA25's specs against your fault current before swapping.

What is the depth of 3RV2021-4DA20-ZX95?

97 mm. That fits standard 120 mm enclosures with clearance for rear wiring.

MPN
3RV2021-4DA20-ZX95