Skip to main content
Siemens 3RV2021-4EA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2021-4EA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2021-4EA10-ZW96
Active

Siemens SIRIUS 3RV2021-4EA10-ZW96 motor protection circuit breaker, CLASS 10 trip, 25 kA at 400 V, 45 mm wide, screw and snap-on 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2021-4EA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0

Electrical

3RV2021-4EA10-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)32 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)13.25 W
Power loss, per pole (AC, hot)4.4 W

Protection & Tripping

3RV2021-4EA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range27 ... 32 A
Instantaneous short-circuit trip current400 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)55 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2021-4EA10-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2021-4EA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²

Mechanical

3RV2021-4EA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2021-4EA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2021-4EA10-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor Protection Circuit Breaker, CLASS 10

The Siemens 3RV2021-4EA10-ZW96 is a SIRIUS motor protection circuit breaker designed to protect motors against overload and short-circuit. It carries a CLASS 10 trip characteristic, meaning it will trip within 10 seconds at 7.2× the thermal setting, matching the heating curve of standard induction motors during a locked-rotor event. Rated for 25 kA breaking capacity at 400 V, it clears line-side faults up to that level without upstream fusing. The unit also provides phase-failure detection, so a lost phase on a three-phase motor will trip within the thermal curve. Mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715. The 45 mm width fits standard panel spacing; depth is 97 mm, with 50 mm clearance required above and below, zero forwards or backwards, and 30 mm at the sides.

Wiring & Integration

Main circuit terminals are screw-type, accepting 2×(1–2.5 mm²) or 2×(2.5–10 mm²) solid or stranded conductors. Terminal screws are M4. Mounting position is any orientation, which simplifies panel layout. Operating temperature range is –20 to +60 °C; storage and transport range is –50 to +80 °C. The unit is rated for a maximum of 15 switching operations per hour under AC-3 duty.

Frequently asked questions

Where can I buy 3RV2021-4EA10-ZW96?

The part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3RV2021-4EA10-ZW96 at 400 V?

It is rated for 25 kA at 400 V.

What is the trip class of this circuit breaker?

CLASS 10 — trips within 10 seconds at 7.2× the thermal setting.

What clearance is needed around the 3RV2021-4EA10-ZW96?

50 mm upwards and downwards, 30 mm at the sides, zero forwards and backwards.

MPN