Skip to main content
Siemens 3RV2021-4EA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2021-4EA10-ZW97 SIRIUS Motor Circuit Breaker, Cla

MPN3RV2021-4EA10-ZW97
Active

Siemens SIRIUS 3RV2021-4EA10-ZW97 motor-protective circuit breaker, Class 10 trip, 45 mm wide, 97 mm depth, screw terminals, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2021-4EA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV2021-4EA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)32 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)13.25 W
Power loss, per pole (AC, hot)4.4 W
3RV2021-4EA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range27 ... 32 A
Instantaneous short-circuit trip current400 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)55 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2021-4EA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2021-4EA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
3RV2021-4EA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2021-4EA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2021-4EA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Breaking capacity and motor ratings

This breaker delivers 100 kA breaking capacity at 240 V, 25 kA at 400 V, 5 kA at 500 V, and 2 kA at 690 V. Motor horsepower ratings span 2 hp at 110/120 V up to 20 hp at 460/480 V, with a 5 hp rating at 230 V and 10 hp at 220/230 V.

Required clearances: 50 mm upward and downward, 30 mm to the side, zero forward or backward. The M4 main contact terminals accept 2×(1–2.5 mm²) or 2×(2.5–10 mm²) solid or stranded wire.

Frequently asked questions

What are the key ratings of the 3RV2021-4EA10-ZW97?

It is a Class 10 motor-protective circuit breaker with 100 kA breaking capacity at 240 V, 25 kA at 400 V, and motor ratings up to 20 hp at 460/480 V. It includes phase failure detection and mounts on a 35 mm DIN rail.

Where can I buy the 3RV2021-4EA10-ZW97?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest functional second-source to the 3RV2021-4EA10-ZW97?

The 3RV2021-4NA25 is a peer in the same SIRIUS family. Both are Class 10 motor-protective breakers with similar DIN-rail footprint, but the 4NA25 variant may have different breaking capacity or accessory options — verify the specific ratings against your BOM before substituting.

MPN
3RV2021-4EA10-ZW97