Siemens 3RV2021-4EA20-0BA0 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2021-4EA20-0BA0 SIRIUS Motor Protection Circuit B

MPN3RV2021-4EA20-0BA0
Active

Siemens SIRIUS motor protection circuit breaker, size S0, CLASS 10, A-release 27-32 A, N-release 400 A, spring-type terminals, 100 kA breaking capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2021-4EA20-0BA0 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker

Electrical

3RV2021-4EA20-0BA0 — Electrical
ParameterValue
Rated operational current (Ie)32 A
Rated voltage20 ... 690 V

Protection & Tripping

3RV2021-4EA20-0BA0 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current400 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)25 kA
Breaking capacity at 400 V (AC)25 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA

Specifications

3RV2021-4EA20-0BA0 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Other specifications

3RV2021-4EA20-0BA0 — Other specifications
ParameterValue
At 400 V rated value25 kA
At 500 V rated value5 kA
Substance prohibitance10/01/2009

Product details

Motor protection breaker for the wet line

The Siemens SIRIUS 3RV2021-4EA20-0BA0 is a motor protection circuit breaker in the S0 frame, designed to protect three-phase motors from overload and short-circuit conditions. It carries a CLASS 10 trip class, meaning it will trip within 10 seconds at 7.2× the set current — fast enough to protect standard induction motors during a stalled-rotor start, but not so fast that it nuisance-trips during a normal acceleration. The adjustable overload release covers 27 to 32 A, and the fixed magnetic short-circuit release fires at 400 A. Rated operational current is 32 A, and the breaker handles fault currents up to 100 kA at 240 V, 25 kA at 400 V, 5 kA at 500 V, and 2 kA at 690 V. That 100 kA figure at 240 V is the headline number — it means this breaker can sit upstream of a motor starter on a high-capacity distribution board without needing a current-limiting fuse ahead of it, as long as the prospective short-circuit current at that point stays under 100 kA. The spring-type terminals accept solid or stranded copper up to 10 mm², and the breaker snaps onto a 35 mm DIN rail per DIN EN 60715. It is rated for 500 switching cycles at an ambient temperature down to -50 °C, which covers outdoor or cold-store installations.

Frequently asked questions

What is 3RV2021-4EA20-0BA0's trip class?

It is a CLASS 10 trip class breaker, meaning it will trip within 10 seconds at 7.2× the set overload current — suitable for standard motor starting profiles.

What is the breaking capacity of 3RV2021-4EA20-0BA0 at different voltages?

At 240 V it is rated for 100 kA; at 400 V, 25 kA; at 500 V, 5 kA; and at 690 V, 2 kA. These are the maximum fault currents it can safely interrupt at each voltage level.

Where can I buy 3RV2021-4EA20-0BA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quotation.