Skip to main content
Siemens 3RV2031-4DA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2031-4DA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2031-4DA10
Active

Siemens SIRIUS 3RV2031-4DA10 motor protection circuit breaker, Class 10 trip, 100 kA breaking capacity at 240 V, screw terminals, DIN rail mount.

$80.01Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2031-4DA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2031-4DA10 — Electrical
ParameterValue
Rated operational current (Ie)25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)14.5 W
Power loss, per pole (AC, hot)4.8 W
3RV2031-4DA10 — Protection & Tripping
ParameterValue
Overload release setting range18 ... 25 A
Instantaneous short-circuit trip current325 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)5 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V3 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2031-4DA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV2031-4DA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 16 mm²), 1x (1 ... 25 mm²)
Conductor range, AWG (main contacts)2x (18 ... 3), 1x (18 ... 2)
3RV2031-4DA10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2031-4DA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2031-4DA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker with Class 10 trip and 100 kA SCCR

The Siemens 3RV2031-4DA10 is a SIRIUS motor protection circuit breaker with a Class 10 trip characteristic. Its interrupting capacity reaches 100 kA at 240 V and 30 kA at 400 V, so it can be applied on high-fault panels without an upstream current-limiting fuse for most industrial services up to 400 V. Phase failure detection is built in, which prevents single-phasing damage on three-phase motors — a common failure mode that a standard thermal-magnetic breaker would not catch.

Mounting and panel integration

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, with any mounting position allowed. Required clearances: 50 mm above and below, 10 mm at the sides — these are the minimum air gaps for arc quenching and heat dissipation, not optional for the rated breaking capacity. Dimensions are 55 mm wide, 140 mm high, 149 mm deep — fits a standard 55 mm modular device footprint on the DIN rail.

MPN