Siemens 3RV2031-4DA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2031-4DA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2031-4DA10-ZX95

Siemens SIRIUS motor protection circuit breaker, 3RV2031-4DA10-ZX95, Class 10, screw terminals, 55 mm wide, for 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2031-4DA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2

Electrical

3RV2031-4DA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)14.5 W
Power loss, per pole (AC, hot)4.8 W

Protection & Tripping

3RV2031-4DA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range18 ... 25 A
Instantaneous short-circuit trip current325 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)5 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V3 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2031-4DA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV2031-4DA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 16 mm²), 1x (1 ... 25 mm²)

Mechanical

3RV2031-4DA10-ZX95 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2031-4DA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2031-4DA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The 3RV2031-4DA10-ZX95: Trip Class 10 means it clears a locked-rotor condition within 10 seconds at 7.2× rated current — standard for most general-purpose motor loads like pumps, fans, and small conveyors. Phase failure detection is built in, so a single-phased motor won't cook before the bimetal catches it. Rated short-circuit breaking capacity at 400 V is 30 kA, dropping to 6 kA at 500 V and 3 kA at 690 V. That 30 kA at 400 V is enough for most industrial panel buswork without needing a current-limiting upstream device.

Mounting and wiring

Snaps onto 35 mm DIN rail per DIN EN 60715 — screw and snap-on both work. Width is 55 mm, depth 149 mm, height 140 mm. Clearance: 50 mm above and below, 10 mm to the side, zero forward or backward. That 55 mm footprint is standard for this frame size; it'll drop into a panel laid out for a 3RV20 series breaker without re-drilling the rail. Main circuit terminals accept 2× (1–25 mm²) or 1× (1–35 mm²) solid or stranded copper. Screw-type terminals, M6 on the main contacts. Torque them properly — loose connections on a motor circuit breaker are a fire risk, not just a nuisance trip.

Frequently asked questions

Where can I buy 3RV2031-4DA10-ZX95?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3RV2031-4DA10-ZX95 drop into a panel specified for 3RV2023-4DA10?

Both are 55 mm wide SIRIUS motor protection breakers on the same DIN-rail footprint. The 3RV2031 carries higher SCCR ratings (30 kA vs lower at 400 V) and different trip curves; verify the coordination study before swapping, but the mechanical fit is the same.

What is the depth of 3RV2031-4DA10-ZX95?

149 mm. That's the dimension from the DIN-rail mounting surface to the front of the enclosure. Panel depth must clear this plus wiring space.