Skip to main content
Siemens 3RV2031-4DB15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2031-4DB15-ZX95 SIRIUS Motor Protection CB, 30 kA

MPN3RV2031-4DB15-ZX95

Siemens SIRIUS, motor protection circuit breaker, 3RV2031-4DB15-ZX95, Class 20, 30 kA at 400 V, screw and snap-on 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2031-4DB15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2

Electrical

3RV2031-4DB15-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)25 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)14.5 W
Power loss, per pole (AC, hot)4.8 W

Protection & Tripping

3RV2031-4DB15-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range18 ... 25 A
Instantaneous short-circuit trip current325 A
Trip classCLASS 20
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)12 kA
Breaking capacity at 690 V (AC)5 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V3 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2031-4DB15-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV2031-4DB15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2031-4DB15-ZX95 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2031-4DB15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2031-4DB15-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What this breaker does on your line

The Siemens 3RV2031-4DB15-ZX95 is a SIRIUS motor protection circuit breaker — the thing that sits between your contactor and the motor, watching for overload and short-circuit. Trip Class 20 means it lets a motor pull starting current for up to 20 seconds before tripping, which covers most standard induction motors on pumps, fans, and compressors. The 30 kA interrupting rating at 400 V means it can clear a bolted fault without upstream fuses needing to help — that's the number your panel SCCR study cares about. Mounts on 35 mm DIN rail per EN 60715, screw or snap-on, any orientation. At 55 mm wide it takes one standard module slot — leaves room for the contactor and overload block next to it. Rated for 20–690 V operating range, so it covers 400 V and 480 V common in industrial panels without derating.

Mounting and panel fit

Screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. Mounting position any — horizontal, vertical, upside-down, doesn't care. Depth 149 mm, width 55 mm, height 140 mm. Clearance: 50 mm above and below, 10 mm at the sides, zero forward or backward. Main contact terminals take M6 screws; solid or stranded wire up to 2x 2.5 mm².

Frequently asked questions

How do I get current pricing and availability for 3RV2031-4DB15-ZX95?

Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is 3RV2031-4DB15-ZX95's interrupting rating at 400 V?

30 kA at 400 V rated value — that's the short-circuit breaking capacity you need for your SCCR calculation.

Will 3RV2031-4DB15-ZX95 drop into a panel that was specified around 3RV2021-4NA25 without rewiring?

Both are SIRIUS motor protection breakers on the same 55 mm DIN-rail footprint, but the 3RV2031 carries higher interrupting capacity (30 kA vs lower values on the 3RV2021). Check your fault current study — if the panel requires 30 kA, the 3RV2031 is the correct fit; if the original spec was lower, the 3RV2031 still works but costs more. Wiring terminals and clearance dimensions are the same.

What compliance documentation does this brand provide for 3RV2031-4DB15-ZX95?

As a Siemens SIRIUS product, it carries CE marking and is designed to meet IEC/EN 60947 standards for motor protection circuit breakers. RoHS and REACH declarations are available through Siemens' documentation portal.

MPN
3RV2031-4DB15-ZX95