Siemens SIRIUS motor protection circuit breaker, 3RV2031-4EB10, 32 A rated current, 30 kA breaking capacity at 400 V, Class 20 trip, screw terminals, snap-on DIN rail mounting.

$109.22Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2031-4EB10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2031-4EB10 — Electrical
ParameterValue
Rated operational current (Ie)32 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)18 W
Power loss, per pole (AC, hot)6 W
3RV2031-4EB10 — Protection & Tripping
ParameterValue
Overload release setting range22 ... 32 A
Instantaneous short-circuit trip current416 A
Trip classCLASS 20
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2031-4EB10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV2031-4EB10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 16 mm²), 1x (1 ... 25 mm²)
Conductor range, AWG (main contacts)2x (18 ... 3), 1x (18 ... 2)
3RV2031-4EB10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2031-4EB10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2031-4EB10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

It carries a rated value of 32 A at 480 V and 32 A at 600 V, with a breaking capacity of 30 kA at 400 V — enough to handle most industrial motor branch circuits without cascading upstream. The 20... 690 V rated voltage range covers standard low-voltage motor loads across global 400 V and 480 V networks.

Dimensions are 55 mm wide, 140 mm high, 149 mm deep — a standard three-module footprint that fits most motor control center buckets. The screw-type terminals accept 2x (1... 25 mm²) or 1x (1... 35 mm²) solid or stranded copper, with M6 main contact bolts. Clearance requirements: 50 mm upwards, 50 mm downwards, 10 mm at the side — no extra gap needed at 240 V, but 125 mm at 400 V.

Trip class and operating limits

Class 20 trip means the breaker allows the motor to draw locked-rotor current for up to 20 seconds before tripping — standard for general-purpose induction motors driving pumps, fans, and conveyors. Maximum switching frequency is 15 operations per hour at AC-3 and AC-3e duty.

Frequently asked questions

What is the breaking capacity of 3RV2031-4EB10 at 400 V?

The breaking capacity is 30 kA at 400 V, which is sufficient for most industrial motor branch circuits without requiring upstream current-limiting fuses.

What trip class is 3RV2031-4EB10?

Class 20, meaning it allows locked-rotor current for up to 20 seconds before tripping — standard for general-purpose induction motors.

Where can I buy 3RV2031-4EB10?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN