Siemens 3RV2031-4EB15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2031-4EB15-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2031-4EB15-ZX95

Siemens SIRIUS 3RV2031-4EB15-ZX95 motor protection circuit breaker, 32 A rated current, 30 kA breaking capacity at 400 V, CLASS 20 trip class, screw and snap-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2031-4EB15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2031-4EB15-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)32 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)18 W
Power loss, per pole (AC, hot)6 W
3RV2031-4EB15-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range22 ... 32 A
Instantaneous short-circuit trip current416 A
Trip classCLASS 20
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2031-4EB15-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV2031-4EB15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2031-4EB15-ZX95 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2031-4EB15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2031-4EB15-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Breaking capacity hits 30 kA at 400 V, 100 kA at 240 V, and still holds 2 kA at 690 V — enough to clear a fault upstream of most downstream contactors without cascading.

The 32 A rating at 480 V and 32 A at 600 V means this breaker directly protects a motor drawing up to 32 A full-load — typical for a 15 kW (20 hp) 400 V motor or a 10 hp 480 V motor, depending on service factor. CLASS 20 trip allows up to 20 seconds at 600% of rated current before opening — enough for high-inertia loads like fans or compressors, but not for extremely long-start loads that would need CLASS 30. Terminals accept 2x (0.5... 1.5 mm²) or 2x (0.75... 2.5 mm²) solid or stranded, with M6 main contact bolts — standard for panel wiring up to 32 A.

Operating environment and clearances

Dimensions: 55 mm wide, 140 mm tall, 149 mm deep — fits standard 55 mm-wide DIN-rail slots.

Frequently asked questions

What are the mounting requirements for 3RV2031-4EB15-ZX95?

Screw and snap-on onto 35 mm DIN rail per DIN EN 60715, any mounting position, with 50 mm clearance above and below, 10 mm at the sides.

MPN
3RV2031-4EB15-ZX95