Siemens 3RV2031-4JA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2031-4JA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2031-4JA10-ZX95

Siemens SIRIUS 3RV2031-4JA10-ZX95, motor protection circuit breaker, CLASS 10, 30 kA breaking capacity at 400 V, screw terminals, 55 mm wide, for 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2031-4JA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2

Electrical

3RV2031-4JA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)65 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)26 W
Power loss, per pole (AC, hot)8.7 W

Protection & Tripping

3RV2031-4JA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range54 ... 65 A
Instantaneous short-circuit trip current845 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)8 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2031-4JA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)20 000
Endurance, auxiliary contacts (typ.)20 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV2031-4JA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 25 mm²), 1x (1 ... 35 mm²)

Mechanical

3RV2031-4JA10-ZX95 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2031-4JA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2031-4JA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens 3RV2031-4JA10-ZX95 is a SIRIUS motor protection circuit breaker, designed for motor protection with CLASS 10 trip characteristics — it opens within 10 seconds at 7.2× rated current, fast enough to protect standard induction motors from locked-rotor damage. Rated breaking capacity hits 30 kA at 400 V, so it can safely interrupt fault currents up to that level without cascading upstream. Phase failure detection is built in, meaning it trips if one phase drops out, preventing single-phasing on a motor load.

Mounting and integration

Snaps onto 35 mm DIN rail per DIN EN 60715, screw and snap-on mounting. Clearance requirements: 50 mm above and below, 10 mm to the side, zero forward or backward. The 55 mm width means it occupies three standard 18 mm module positions on the rail — plan your enclosure fill accordingly. Screw terminals on the main circuit accept 2×(1…35 mm²) or 1×(1…50 mm²) solid or stranded copper.

Rating breakdown

Breaking capacity varies by voltage: 100 kA at 240 V, 30 kA at 400 V, 4 kA at 500 V, 2 kA at 690 V. Motor power ratings: 18.5 kW at 230 V, 25 hp at 220/230 V, 50 hp at 460/480 V. Rated voltage span is 20…690 V. Maximum switching frequency in AC-3 duty is 15 operations per hour. Ambient operating temperature range is -20 to +60 °C.

Frequently asked questions

What are the key ratings for 3RV2031-4JA10-ZX95?

CLASS 10 trip, 30 kA breaking capacity at 400 V, 18.5 kW at 230 V, 50 hp at 460/480 V. Phase failure detection included. Screw terminals, 55 mm wide, mounts on 35 mm DIN rail.

Where can I buy 3RV2031-4JA10-ZX95?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

Will 3RV2031-4JA10-ZX95 drop into a panel specified around 3RV2021-4NA25?

Both are SIRIUS motor protection circuit breakers on 55 mm wide bodies for 35 mm DIN rail, so the footprint and mounting are identical. The 3RV2031-4JA10-ZX95 carries higher breaking capacity (30 kA vs. the 3RV2021 family's typical 15 kA at 400 V) and includes phase failure detection — verify the trip class and rated current match your motor nameplate before swapping.

What compliance documentation does Siemens provide for 3RV2031-4JA10-ZX95?

Standard Siemens SIRIUS documentation includes RoHS and REACH declarations, plus IEC/EN 60947-2 and UL 489 certifications. Specific certificate numbers and declaration dates are available on request with an RFQ.