Siemens 3RV2031-4JA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2031-4JA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2031-4JA10-ZX95

Siemens SIRIUS 3RV2031-4JA10-ZX95, motor protection circuit breaker, CLASS 10, 30 kA breaking capacity at 400 V, screw terminals, 55 mm wide, for 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2031-4JA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2031-4JA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)65 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)26 W
Power loss, per pole (AC, hot)8.7 W
3RV2031-4JA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range54 ... 65 A
Instantaneous short-circuit trip current845 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)8 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2031-4JA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)20 000
Endurance, auxiliary contacts (typ.)20 000
Switching frequency, AC-3 (max.)15 1/h
3RV2031-4JA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
3RV2031-4JA10-ZX95 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2031-4JA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2031-4JA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens 3RV2031-4JA10-ZX95 is a SIRIUS motor protection circuit breaker, designed for motor protection with CLASS 10 trip characteristics — it opens within 10 seconds at 7.2× rated current, fast enough to protect standard induction motors from locked-rotor damage.

Clearance requirements: 50 mm above and below, 10 mm to the side, zero forward or backward. The 55 mm width means it occupies three standard 18 mm module positions on the rail — plan your enclosure fill accordingly. Screw terminals on the main circuit accept 2×(1…35 mm²) or 1×(1…50 mm²) solid or stranded copper.

Rating breakdown

Breaking capacity varies by voltage: 100 kA at 240 V, 30 kA at 400 V, 4 kA at 500 V, 2 kA at 690 V. Motor power ratings: 18.5 kW at 230 V, 25 hp at 220/230 V, 50 hp at 460/480 V. Rated voltage span is 20…690 V. Maximum switching frequency in AC-3 duty is 15 operations per hour.

Frequently asked questions

What are the key ratings for 3RV2031-4JA10-ZX95?

CLASS 10 trip, 30 kA breaking capacity at 400 V, 18.5 kW at 230 V, 50 hp at 460/480 V. Phase failure detection included. Screw terminals, 55 mm wide, mounts on 35 mm DIN rail.

Where can I buy 3RV2031-4JA10-ZX95?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

Will 3RV2031-4JA10-ZX95 drop into a panel specified around 3RV2021-4NA25?

Both are SIRIUS motor protection circuit breakers on 55 mm wide bodies for 35 mm DIN rail, so the footprint and mounting are identical. The 3RV2031-4JA10-ZX95 carries higher breaking capacity (30 kA vs. the 3RV2021 family's typical 15 kA at 400 V) and includes phase failure detection — verify the trip class and rated current match your motor nameplate before swapping.

What compliance documentation does Siemens provide for 3RV2031-4JA10-ZX95?

Standard Siemens SIRIUS documentation includes RoHS and REACH declarations, plus IEC/EN 60947-2 and UL 489 certifications. Specific certificate numbers and declaration dates are available on request with an RFQ.

MPN
3RV2031-4JA10-ZX95