Skip to main content
Siemens 3RV2031-4UA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2031-4UA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2031-4UA10
Active

Siemens SIRIUS 3RV2031-4UA10 motor protection circuit breaker, 40 A at 480 V, 30 kA breaking capacity at 400 V, Trip Class 10, screw and snap-on 35 mm DIN rail mount.

$101.60Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2031-4UA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2031-4UA10 — Electrical
ParameterValue
Rated operational current (Ie)40 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)20 W
Power loss, per pole (AC, hot)6.7 W
3RV2031-4UA10 — Protection & Tripping
ParameterValue
Overload release setting range32 ... 40 A
Instantaneous short-circuit trip current585 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2031-4UA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV2031-4UA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 16 mm²), 1x (1 ... 25 mm²)
Conductor range, AWG (main contacts)2x (18 ... 3), 1x (18 ... 2)
3RV2031-4UA10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2031-4UA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2031-4UA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Its headline rating is 40 A at 480 V and 30 kA breaking capacity at 400 V — that 30 kA is the maximum fault current it can safely interrupt at 400 V, so on a 400 V line with a prospective short-circuit current up to 30 kA, this breaker clears the fault without upstream damage.

The breaker measures 55 mm wide and 149 mm deep, with a height of 140 mm. That 55 mm width is a single modular unit — it occupies one 55 mm slot on the DIN rail, leaving room for adjacent devices. Terminal capacity on the main contacts accepts 2x (1... 25 mm²) or 1x (1... 35 mm²) solid or stranded wire, with M6 screw terminals.

Frequently asked questions

What is the breaking capacity of 3RV2031-4UA10 at 400 V?

The breaking capacity is 30 kA at 400 V. That is the maximum fault current it can safely interrupt at that voltage.

What are the mounting dimensions for 3RV2031-4UA10?

Width is 55 mm, depth is 149 mm, height is 140 mm. It mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715.

Where can I buy 3RV2031-4UA10?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV2031-4UA10