Skip to main content
Siemens 3RV2031-4UB10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2031-4UB10 SIRIUS Motor Protection Circuit Breake

MPN3RV2031-4UB10
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2031-4UB10, 55 mm width, CLASS 20 trip, 30 kA at 400 V, screw and snap-on DIN rail mounting.

$120.65Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2031-4UB10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2031-4UB10 — Electrical
ParameterValue
Rated operational current (Ie)40 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)20 W
Power loss, per pole (AC, hot)6.7 W
3RV2031-4UB10 — Protection & Tripping
ParameterValue
Overload release setting range32 ... 40 A
Instantaneous short-circuit trip current585 A
Trip classCLASS 20
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2031-4UB10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV2031-4UB10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 16 mm²), 1x (1 ... 25 mm²)
Conductor range, AWG (main contacts)2x (18 ... 3), 1x (18 ... 2)
3RV2031-4UB10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2031-4UB10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2031-4UB10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker, 55 mm, CLASS 20 trip

Its CLASS 20 trip characteristic provides a 20-second overload response at 7.2× I_e, matching the thermal curve of standard NEMA-design B and IEC motors. The 55 mm width (3.5 module spaces on a 35 mm DIN rail per DIN EN 60715) and 149 mm depth fit standard motor-starter footprints. Screw-type terminals on the main circuit accept 2× (1 to 25 mm²) or 1× (1 to 35 mm²) solid or stranded copper — no ferrule required for the larger cross-section.

Clearance and mounting

Clearance requirements vary with system voltage: at 240 V no clearance is required; at 400 V allow 125 mm upwards and 50 mm downwards; at 500 V allow 100 mm upwards; at 690 V allow 80 mm upwards. Side clearance is 10 mm. These distances ensure arc-fault containment and thermal dissipation — critical when the breaker is packed into a dense panel.

Frequently asked questions

What is 3RV2031-4UB10's width and depth?

The width is 55 mm and the depth is 149 mm, fitting a standard 3.5-module DIN-rail footprint.

What breaking capacity does 3RV2031-4UB10 have at 400 V?

30 kA at 400 V AC, sufficient for most industrial service-entrance and distribution panels.

Where can I buy 3RV2031-4UB10 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does 3RV2031-4UB10 include phase failure detection?

Yes, phase failure detection is built in; ground fault detection is not.

MPN