Siemens 3RV2031-4UB15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2031-4UB15 SIRIUS Motor Protection Circuit Breake

MPN3RV2031-4UB15
Active

Siemens SIRIUS 3RV2031-4UB15 motor protection circuit breaker, Trip Class 20, 30 kA breaking capacity at 400 V, screw and snap-on mounting onto 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2031-4UB15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2

Electrical

3RV2031-4UB15 — Electrical
ParameterValue
Rated operational current (Ie)40 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)20 W
Power loss, per pole (AC, hot)6.7 W

Protection & Tripping

3RV2031-4UB15 — Protection & Tripping
ParameterValue
Overload release setting range32 ... 40 A
Instantaneous short-circuit trip current585 A
Trip classCLASS 20
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2031-4UB15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h

Connections

3RV2031-4UB15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 3), 1x (18 ... 2)

Mechanical

3RV2031-4UB15 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2031-4UB15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2031-4UB15 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

SIRIUS 3RV2031-4UB15 — motor protection circuit breaker

The Siemens SIRIUS 3RV2031-4UB15 is a motor protection circuit breaker designed for protecting three-phase induction motors against overload and short-circuit conditions. It mounts via screw and snap-on onto 35 mm standard mounting rail per DIN EN 60715, fitting into any standard control panel enclosure. Rated Trip Class 20, meaning it allows a motor to draw up to 20 times its full-load current for 20 seconds before tripping — appropriate for loads with moderate starting inertia like conveyors, pumps, and compressors. The breaker includes phase failure detection, which will trip if one phase is lost, preventing single-phasing damage to the motor. Breaking capacity is 30 kA at 400 V AC, with a higher 100 kA at 240 V. The 30 kA figure at 400 V is the rating that governs coordination with upstream protection in a 400 V three-phase panel — it must be matched to the available fault current at the installation point. The voltage range spans 20 to 690 V, covering standard low-voltage motor circuits.

Dimensions and mounting

Width is 55 mm, depth 149 mm, height 140 mm. The 55 mm width occupies three 18 mm modular spaces on a DIN rail — a standard footprint for this class of motor-protective device. Clearance requirements: 50 mm above and below for air circulation and arc venting, 10 mm at the sides. Mounting position is any orientation, which simplifies panel layout when space is constrained. Main contact terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire — sized for motor feeder cables up to 2.5 mm².

Frequently asked questions

What is the breaking capacity of 3RV2031-4UB15 at 400 V?

30 kA at 400 V AC, which is the rating that determines its suitability for installation in panels with available fault current up to that level.

Will 3RV2031-4UB15 drop into a panel specified around 3RV2021-4NA25 without rewiring?

Both are 55 mm wide SIRIUS motor protection breakers on the same DIN-rail footprint, so the mechanical fit is the same. The 3RV2031-4UB15 carries a higher 30 kA breaking capacity at 400 V versus the 3RV2021-4NA25's lower rating — verify the available fault current at the panel before swapping. Terminal wire sizes are identical.

What compliance documentation does Siemens provide for 3RV2031-4UB15?

The product carries the SIRIUS brand and is designed to meet IEC/EN 60947-2 and 60947-4-1 standards for circuit breakers and motor starters. RoHS and REACH declarations are available from Siemens documentation. Specific UL/CSA file numbers are not listed in this evidence set — confirm with the manufacturer for the exact certification markings on the unit.

How do I get current pricing and availability for 3RV2031-4UB15?

Submit an RFQ through the distributor. Availability and current pricing are confirmed at quote time — no stock count or price figure is published here.

MPN
3RV2031-4UB15