Specifications

3RV2031-4VA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2031-4VA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)45 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)24.5 W
Power loss, per pole (AC, hot)8.2 W
3RV2031-4VA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range35 ... 45 A
Instantaneous short-circuit trip current650 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2031-4VA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV2031-4VA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 16 mm²), 1x (1 ... 25 mm²)
Conductor range, AWG (main contacts)2x (18 ... 3), 1x (18 ... 2)
3RV2031-4VA10-ZW97 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV2031-4VA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2031-4VA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The 55 mm width and 149 mm depth fit standard panel layouts; clearance requirements are 50 mm upward, 50 mm downward, and 10 mm to the side — no extra space needed forward or backward.

Integration Notes

Screw-type terminals on the main circuit accept 2×(1–25 mm²) or 1×(1–35 mm²) solid or stranded copper. Terminal size M6 for the main contacts. Temperature compensation is active across the -20 to +60 °C operating range. Maximum switching frequency under AC-3 duty is 15 operations per hour — adequate for motor starting applications but not for high-cycling loads like rapid reversing or jogging. For higher duty cycles, consider a contactor with a higher mechanical life rating.

Frequently asked questions

Where can I buy 3RV2031-4VA10-ZW97 and get a price?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the breaking capacity of 3RV2031-4VA10-ZW97 at 400 V?

The breaking capacity at 400 V is 30 kA. At 690 V it is 2 kA, and at 240 V it is 100 kA.

Will 3RV2031-4VA10-ZW97 drop into a panel specified around 3RV1011-1HA10?

The 3RV2031-4VA10-ZW97 is a SIRIUS motor protection circuit breaker with a 55 mm width and DIN-rail mounting, similar in form factor to the 3RV1011 series. However, verify the terminal size and clearance requirements against your existing panel layout — the 3RV2031 uses M6 main terminals and requires 50 mm upward clearance, which may differ from the 3RV1011.

MPN
3RV2031-4VA10-ZW97