3RV2031-4XA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2031-4XA15 — Electrical
ParameterValue
Rated operational current (Ie)59 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)26 W
Power loss, per pole (AC, hot)8.7 W
3RV2031-4XA15 — Protection & Tripping
ParameterValue
Overload release setting range49 ... 59 A
Instantaneous short-circuit trip current845 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)65 kA
Breaking capacity at 400 V (AC)65 kA
Breaking capacity at 500 V (AC)8 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2031-4XA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)20 000
Endurance, auxiliary contacts (typ.)20 000
Switching frequency, AC-3 (max.)15 1/h
3RV2031-4XA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 1)
3RV2031-4XA15 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2031-4XA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2031-4XA15 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Panel footprint and integration

Footprint is 55 mm wide by 149 mm deep by 140 mm tall — a single-module width on the rail. Mounting position any, which helps when you're squeezing it into a gland-plate corner. Upwards and downwards clearance is 50 mm each; at the side it's only 10 mm, so you can pack breakers tight in a multi-motor group.

Current production — the lifecycle stage is listed as active. This is not an NRND or obsolete part. No official successor exists because none is needed.

Frequently asked questions

What are the key ratings for 3RV2031-4XA15?

CLASS 10 trip class, 30 kA SCCR at 400 V, 100 kA at 240 V, phase failure detection. Mounts on 35 mm DIN rail, footprint is 55 mm wide by 149 mm deep.

Where can I buy 3RV2031-4XA15?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does 3RV2031-4XA15 have phase failure detection?

Yes, phase failure detection is built into this motor protection circuit breaker.