Siemens 3RV2032-4JA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2032-4JA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2032-4JA10-ZX95

Siemens SIRIUS 3RV2032-4JA10-ZX95 motor protection circuit breaker, Class 10, 50 kA at 400 V, screw terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2032-4JA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2032-4JA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)65 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)26 W
Power loss, per pole (AC, hot)8.7 W
3RV2032-4JA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range54 ... 65 A
Instantaneous short-circuit trip current845 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2032-4JA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)20 000
Endurance, auxiliary contacts (typ.)20 000
Switching frequency, AC-3 (max.)15 1/h
3RV2032-4JA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
3RV2032-4JA10-ZX95 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2032-4JA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2032-4JA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker for 400 V panels

The main contacts use M6 screw terminals, and the wiring range accepts 2x 1–35 mm² or 1x 1–50 mm² solid or stranded — sized for the motor feed conductors typical at this rating.

Dimensions are 55 mm wide, 140 mm high, 149 mm deep — a standard SIRIUS 3RV2 footprint that drops into existing panel layouts without re-drilling the subplate.

Frequently asked questions

Where can I buy 3RV2032-4JA10-ZX95 and get a price?

This part is available to order through independent distribution. Submit an RFQ for a confirmed price and lead time — availability is confirmed at quote time.

What is the breaking capacity of 3RV2032-4JA10-ZX95 at 400 V?

The rated breaking capacity is 50 kA at 400 V, which covers most industrial panel fault levels without needing upstream fuses or a current-limiting breaker.

Does 3RV2032-4JA10-ZX95 detect phase failure?

Yes, phase failure detection is included — the breaker will trip if one phase is lost, protecting the motor from single-phasing.

What is the trip class of this breaker?

Trip Class 10, meaning it clears overloads within 10 seconds at 7.2× rated current — suitable for standard motor protection.