Skip to main content
Siemens 3RV2032-4RA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2032-4RA15 SIRIUS Motor Protection Circuit Breake

MPN3RV2032-4RA15
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2032-4RA15, CLASS 10, rated 20-690 V, 160 kA breaking capacity at 400 V, screw terminals, 55 mm wide, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV2032-4RA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2032-4RA15 — Electrical
ParameterValue
Rated operational current (Ie)80 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)29.5 W
Power loss, per pole (AC, hot)9.8 W
3RV2032-4RA15 — Protection & Tripping
ParameterValue
Overload release setting range70 ... 80 A
Instantaneous short-circuit trip current1 040 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2032-4RA15 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)20 000
Endurance, auxiliary contacts (typ.)20 000
Switching frequency, AC-3 (max.)15 1/h
3RV2032-4RA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 1)
3RV2032-4RA15 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2032-4RA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2032-4RA15 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker for panel integration

The Siemens 3RV2032-4RA15 is a SIRIUS motor protection circuit breaker designed for Class 10 trip response, meaning it disconnects within 10 seconds at 7.2× the thermal setting — fast enough to protect standard induction motors against locked-rotor events without nuisance tripping on normal starts. It carries a rated operational voltage range of 20 to 690 V and delivers a breaking capacity of 160 kA at 400 V, 125 kA at 500 V, and 100 kA at 690 V, so it can interrupt high-fault currents in industrial distribution without upstream coordination. The auxiliary contact block supports 1 A at 24 V, 0.15 A at 60 V, and 0.5 A at 230 V, covering PLC-level signal feedback.

Main circuit terminals are M6 screw-type, accepting 2×(0.5–1.5 mm²) or 2×(0.75–2.5 mm²) solid or stranded conductors.

Frequently asked questions

Where can I buy 3RV2032-4RA15 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for current pricing and availability.

What is the breaking capacity of 3RV2032-4RA15 at 400 V?

160 kA at 400 V, with 125 kA at 500 V and 100 kA at 690 V.

What trip class is 3RV2032-4RA15?

CLASS 10 — disconnects within 10 seconds at 7.2× the thermal setting, suitable for standard motor starting profiles.

MPN
3RV2032-4RA15