Siemens 3RV2032-4VA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2032-4VA10 SIRIUS Motor Protection Circuit Breake

MPN3RV2032-4VA10
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2032-4VA10, Class 10 trip, 50 kA at 400 V, screw terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2032-4VA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV2032-4VA10 — Electrical
ParameterValue
Rated operational current (Ie)45 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)24.5 W
Power loss, per pole (AC, hot)8.2 W
3RV2032-4VA10 — Protection & Tripping
ParameterValue
Overload release setting range35 ... 45 A
Instantaneous short-circuit trip current650 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)15 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2032-4VA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)50 000
Endurance, auxiliary contacts (typ.)50 000
Switching frequency, AC-3 (max.)15 1/h
3RV2032-4VA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 1)
3RV2032-4VA10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2032-4VA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2032-4VA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The 3RV2032-4VA10 carries a 100 kA breaking capacity at 240 V and 50 kA at 400 V. The rated voltage range is 20 to 690 V, so it covers 400 V three-phase and 480 V systems common in North American industrial panels. Horsepower ratings: 10 hp at 230 V, 15 hp at 200/208 V, 40 hp at 460/480 V, and 50 hp at 575/600 V. The 45 A continuous rating at 480 V and 600 V gives the steady-state current the breaker will carry without tripping — match this to the motor FLA, not the horsepower nameplate alone.

Mounting and wiring — panel integration

Any mounting position is allowed. Clearance requirements: 50 mm upwards, 50 mm downwards, 10 mm at the side — but at 240 V no clearance is required, so in a 240 V panel you can pack it tighter. At 400 V you need 125 mm upwards, at 500 V 100 mm, at 690 V 80 mm. That upward clearance is for arc flash venting; don't skip it on higher-voltage builds. Main circuit terminals are screw-type, accepting 2× (1 to 35 mm²) or 1× (1 to 50 mm²) solid or stranded copper. Terminal size is M6. The 55 mm width and 140 mm height with 149 mm depth mean it occupies a standard three-module-wide footprint on the DIN rail — plan for that in your enclosure fill factor.

Frequently asked questions

How do I get current pricing and availability for 3RV2032-4VA10?

The 3RV2032-4VA10 is sourced and quoted to order against an RFQ. Submit a request through the storefront; availability and current pricing are confirmed at quote time.

Will 3RV2032-4VA10 drop into a panel specified around 3RV2023-4DA10 without rewiring?

The 3RV2032-4VA10 is a larger-frame breaker than the 3RV2023-4DA10. The 3RV2032-4VA10 has a 55 mm width versus the 3RV2023-4DA10's 45 mm width, so it will not fit the same DIN rail footprint without moving adjacent devices. Wiring terminals are screw-type on both, but the 3RV2032-4VA10 accepts larger conductors — up to 50 mm² — so if your existing wiring is sized for the smaller breaker, it will terminate fine, but you will need to re-lay out the rail spacing.

MPN
3RV2032-4VA10